Description: Suction fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the FM8 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM8 operation check. 4 Change FM8. 5 Change PRCB.
Code: C0351
Description: Paper cooling fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the FM7 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM7 operation check. 4 Change FM7. 5 Change PRCB.