Các lỗi thường gặp

Code :
  • Code: C3721
  • Description: Fusing abnormally high temperature detection (heating side)
    • The heating roller thermistor continues to detect a temperature higher than a predetermined one for a predetermined period of time. • Hard protection signal L is detected continuously over a predetermined period of time.
  • Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, PRCB and DCPU for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.
  • Code: C3723
  • Description: Fusing abnormally high temperature detection (pressurizing side)
    • The temperature of the pressure roller continues to be higher than a predetermined level for a predetermined period of time after a temperature correction.
  • Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, PRCB and DCPU for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU
  • Code: C3821
  • Description: Fusing abnormally low temperature detection (heating side)
    • The heating roller thermistor continues to detect a temperature lower than a predetermined one for a predetermined period of time. • In the states other than a warm-up operation, a zero cross signal cannot be detected after the lapse of a predetermined period of time after the fusing heater is turned ON or OFF. • The power supply frequency cannot be detected.
  • Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, PRCB and DCPU for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.
  • Code: C3823
  • Description: Fusing abnormally low temperature detection (pressurizing side)
    • The temperature of the pressure roller continues to be lower than a predetermined level for a predetermined period of time after a temperature correction.
  • Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, PRCB and DCPU for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change PRCB. 6 Change DCPU.
  • Code: C4151
  • Description: Polygon motor rotation trouble (C)
    • The polygon motor fails to turn stably even after the lapse of a given period of time after activating the polygon motor.
    • Motor lock signal detects HIGH for a given period time consecutively during the polygon motor is rotating.
  • Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change REYB/PH. 4 Change PRCB.
  • Code: C4152
  • Description: Polygon motor rotation trouble (M)
  • Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change REYB/PH. 4 Change PRCB.
  • Code: C4153
  • Description: Polygon motor rotation trouble (Y)
  • Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change REYB/PH. 4 Change PRCB.
  • Code: C4154
  • Description: Polygon motor rotation trouble (K)
  • Remedy: 1 Check the connector for proper connection and correct as necessary. 2 Change PH unit. 3 Change REYB/PH. 4 Change PRCB.