Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub C450P — Trang 11/14

Code: C3452

Description: Fusing Pressure Roller warm-up failure
• The voltage of the Fusing Pressure Roller Thermistor does not increase by five steps within 20 sec. after the predrive of the Fusing Roller has been started during a warm-up cycle.
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PWB-MC and PU1 for proper connection and correct or change as necessary. 3 Change Fusing Unit. 4 Change PWB-MC. 5 Change PU1.

Code: C3461

Description: New Fusing Unit resetting failure
• A new installation is not detected when a new Fusing Unit is installed.
Remedy: 1 Reinstall Unit. 2 Change PWB-MC.

Code: C3751

Description: Heating Roller abnormally high temperature
• A temperature of 225 °C or more of the Heating Roller is detected for 1 sec. or more.
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PWB-MC and PU1 for proper connection and correct or change as necessary. 3 Change Fusing Unit. 4 Change PWB-MC. 5 Change PU1.

Code: C3752

Description: Fusing Pressure Roller abnormally high temperature
• A temperature of 190 °C or more of the Fusing Pressure Roller is detected for 1 sec. or more before the start of the heater temperature control. • A temperature of 215 °C or more of the Fusing Pressure Roller is detected for 1 sec. or more after the start of the heater temperature control.
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PWB-MC and PU1 for proper connection and correct or change as necessary. 3 Change Fusing Unit. 4 Change PWB-MC. 5 Change PU1.

Code: C3851

Description: Heating Roller abnormally low temperature
• No zero cross signal is detected even with the lapse of 1 sec. or more during a standby state, print cycle, or Power Save. • A temperature of 120 °C or less of the Heating Roller is detected for 1 sec. or more during a standby state. • A temperature of 120 °C or less of the Heating Roller is detected for 1 sec. or more during a print cycle. • A temperature of 70 °C or less of the Heating Roller is detected for 1 sec. or more during Power Save.
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PWB-MC and PU1 for proper connection and correct or change as necessary. 3 Change Fusing Unit. 4 Change PWB-MC. 5 Change PU1.

Code: C3852

Description: Fusing Pressure Roller abnormally low temperature
• . A temperature of 80 °C or less of the Fusing Pressure Roller is detected for 1 sec. or more during a standby state. • A temperature of 80 °C or less of the Fusing Pressure Roller is detected for 1 sec. or more during a print cycle. • A temperature of 80 °C or less of the Fusing Pressure Roller is detected for 1 sec. or more during Power Save.
Remedy: 1 Check the Fusing Unit for correct installation (whether it is secured in position). 2 Check the Fusing Unit, PWB-MC and PU1 for proper connection and correct or change as necessary. 3 Change Fusing Unit. 4 Change PWB-MC. 5 Change PU1.

Code: C4705

Description: Printer Time Out
• No image data is output from the MFP Control Board (PWB-MFPC).
Remedy: 1 Select Service Mode - State Confirmation - Memory/HDD Adj. - Memory Bus Check - Memory-PRT. 2 Check the connectors on PWB-MFPC for proper connection and correct as necessary. 3 Change PWB-MFPC.

Code: C4761

Description: Compression hardware timeout
• The hardware involved with the compression function offered by the MFP Control Board (PWBMFPC) does not respond.
Remedy: Change PWB-MFPC
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie