Description: Fusing abnormally high temperature detection (pressurizing side)
• The fusing pressure roller thermistor continues to detect a temperature higher than a predetermined one for a predetermined period of time.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, MFPB and DCPU for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change IHPU. 6 Change PRCB. 7 Change DCPU.
Code: C3724
Description: Fusing abnormally high temperature detection (soaking side)
• The soaking roller thermistor/1 continues to detect a temperature higher than a predetermined one for a predetermined period of time. • The signal is turned ON to activate the hard ratchet on the soaking side.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, MFPB and DCPU for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change IHPU. 6 Change PRCB. 7 Change DCPU.
Code: C3725
Description: Fusing abnormally high temperature detection (NS sensor)
• The NC sensor continues to detect a temperature higher than a predetermined one for a predetermined period of time.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, MFPB and REDB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change IHPU. 6 Change PRCB. 7 Change REDB.
Code: C3822
Description: Fusing abnormally low temperature detection (Edge of the heating roller)
• The heating roller thermistor/2 continues to detect a temperature lower than a predetermined one for a predetermined period of time.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, PRCB and REDB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change IHPU. 6 Change PRCB. 7 Change REDB.
Code: C3823
Description: Fusing abnormally low temperature detection (pressurizing side)
• The fusing pressure roller thermistor continues to detect a temperature lower than a predetermined one for a predetermined period of time.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, PRCB and DCPU for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change IHPU. 6 Change PRCB. 7 Change DCPU.
Code: C3824
Description: Fusing abnormally low temperature detection (soaking side)
• The soaking roller thermistor/1 continues to detect a temperature lower than a predetermined one for a predetermined period of time.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, PRCB and DCPU for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change IHPU. 6 Change PRCB. 7 Change DCPU.
Code: C3825
Description: Fusing abnormally low temperature detection (NC sensor)
• The NC sensor continues to detect a temperature lower than a predetermined one for a predetermined period of time.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, PRCB and REDB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change IHPU. 6 Change PRCB. 7 Change REDB.
Code: C3921
Description: Fusing sensor wire breaks detection (Center of the heating roller)
• At the warm-up stage, the heating roller thermistor/3 voltage does not decrease by predetermined steps (temperature rise) within a predetermined time.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the open/close operation of the upper right door. 3 Check the fusing unit, IHPU, PRCB and REDB for proper connection and correct or change as necessary. 4 Change fusing unit. 5 Change IHPU. 6 Change PRCB. 7 Change REDB.