Description: Color PC drum motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the M16 connector for proper connection and correct as necessary. 2 Check the M16 connector for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M16 operation check PRCB CN12PRCB-9 (REM) PRCB CN12PRCB-12 (LOCK) K-9. 5 Change M16. 6 Change PRCB.
Code: C2255
Description: Color developing motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Remedy: 1 Check the M17 connector for proper connection and correct as necessary. 2 Check the M17 connector for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M17 operation check PRCB CN12PRCB-14 (REM) PRCB CN12PRCB-17 (LOCK) K-8. 5 Change M17. 6 Change PRCB.
Code: C2256
Description: Color developing motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the M17 connector for proper connection and correct as necessary. 2 Check the M17 connector for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M17 operation check PRCB CN12PRCB-14 (REM) PRCB CN12PRCB-17 (LOCK) K-8. 5 Change M17. 6 Change PRCB.
Code: C2257
Description: Cleaner motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Remedy: 1 Check the M38 connector for proper connection and correct as necessary. 2 Check the M38 connector for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M38 operation check PRCB CN13PRCB-11 (LOCK) K-10 to 11. 5 Change M38. 6 Change PRCB.
Code: C2258
Description: Cleaner motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the M38 connector for proper connection and correct as necessary. 2 Check the M38 connector for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M38 operation check PRCB CN13PRCB-11 (LOCK) K-10 to 11. 5 Change M38. 6 Change PRCB.
Code: C2259
Description: K developing motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Remedy: 1 Check the M19 connector for proper connection and correct as necessary. 2 Check the M19 connector for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M19 operation check PRCB CN12PRCB-2 (REM) PRCB CN12PRCB-5 (LOCK) K-9. 5 Change M19. 6 Change PRCB.
Code: C225A
Description: K developing motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the M19 connector for proper connection and correct as necessary. 2 Check the M19 connector for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M19 operation check PRCB CN12PRCB-2 (REM) PRCB CN12PRCB-5 (LOCK) K-9. 5 Change M19. 6 Change PRCB.
Code: C225B
Description: K PC drum motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Remedy: 1 Check the M18 connector for proper connection and correct as necessary. 2 Check the M18 connector for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M18 operation check PRCB CN13PRCB-15 (REM) PRCB CN13PRCB-18 (LOCK) K-10. 5 Change M18. 6 Change PRCB.