Description: Fusing motor failure to turn • The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Causes: Fusing motor (M30) Printer control board (PRCB)
Remedy: 1 Check the M30 connector for proper connection and correct as necessary. - - 2 Check the loading status of the fusing unit drive, and correct the error as necessary. - - 3 Check the fusing unit, PRCB for proper connection and correct or change as necessary. - - 4 M30 operation check PRCB CN9-3 (REM) PRCB CN9-6 (LOCK) K-8 5 Change M30 - - 6 PRCB ICP16 conduction check - - 7 Change PRCB
Description: Fusing motor turning at abnormal timing • The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: Fusing motor (M30) Printer control board (PRCB)
Remedy: 1 Check the M30 connector for proper connection and correct as necessary. - - 2 Check the loading status of the fusing unit drive, and correct the error as necessary. - - 3 Check the fusing unit, PRCB for proper connection and correct or change as necessary. - - 4 M30 operation check PRCB CN9-3 (REM) PRCB CN9-6 (LOCK) K-8 5 Change M30 - - 6 PRCB ICP16 conduction check - - 7 Change PRCB
Description: Fusing cooling fan motor/ 1 failure to turn • The fan motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Causes: Fusing cooling fan motor/1 (FM2) Printer control board (PRCB)
Remedy: 1 Check the FM2 connector for proper connection and correct as necessary. - - 2 Check the fan for possible overload and correct as necessary. - - 3 FM2 operation check PRCB CN11-1 (REM) PRCB CN11-3 (LOCK) K-7 4 Change FM2 - - 5 PRCB ICP9 conduction check - - 6 Change PRCB
Description: Fusing cooling fan motor/ 2 failure to turn • The fan motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Causes: Fusing cooling fan motor/2 (FM4) Paper feed/transport drive board (PFTDB)
Remedy: 1 Check the FM4 connector for proper connection and correct as necessary. - - 2 Check the fan for possible overload and correct as necessary. - - 3 FM4 operation check PFTDB CN5-6 (REM) PFTDB CN5-8 (LOCK) Q-6 4 Change FM4 - - 5 PFTDB ICP2 conduction check - - 6 Change PFTDB
Description: Fusing cooling fan motor/ 3 failure to turn • The fan motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Causes: Fusing cooling fan motor/3 (FM5) Paper feed/transport drive board (PFTDB)
Remedy: 1 Check the FM5 connector for proper connection and correct as necessary. - - 2 Check the fan for possible overload and correct as necessary. - - 3 FM5 operation check PFTDB CN5-9 (REM) PFTDB CN5-11 (LOCK) Q-6 4 Change FM5 - - 5 PFTDB ICP2 conduction check - - 6 Change PFTDB
Description: Fusing heaters trouble (soaking side) • After warm-up operation starts, the soaking roller thermistor does not detect a temperature as high as a predetermined one though a predetermined period of time has elapsed.
Causes: Fusing unit IH power supply (IHPU) DC power supply (DCPU) Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). - - 2 Check the open/close operation of the upper right door. - - 3 Check the fusing unit, IHPU, MFPB and DCPU for proper connection and correct or change as necessary. - - 4 Change fusing unit - - 5 Change IHPU - - 6 Change PRCB - - 7 Change DCPU
Description: Fusing heaters trouble (NC sensor) • After warm-up operation starts, the heating roller temperature sensor/1 does not detect a temperature as high as a predetermined one though a predetermined period of time has elapsed.
Causes: Fusing unit Heating roller temperature sensor/1 (TEMS1) IH power supply (IHPU) Relay drive board (REDB) Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). - - 2 Check the open/close operation of the upper right door. - - 3 Check the fusing unit, IHPU, MFPB and REDB for proper connection and correct or change as necessary. - - 4 Change TEMS1 - - 5 Change fusing unit - - 6 Change IHPU - - 7 PRCB ICP17 conduction check - - 8 Change PRCB - - 9 Change REDB
Description: Fusing abnormally high temperature detection (Center of the heating roller) • The heating roller temperature sensor/2 continues to detect a temperature higher than a predetermined one for a predetermined period of time. • The signal is turned ON to activate the hard ratchet in the middle of the heating side.
Causes: Fusing unit Heating roller temperature sensor/1 (TEMS1) Heating roller temperature sensor/2 (TEMS2) Heating roller temperature sensor/3 (TEMS3) IH power supply (IHPU) Relay drive board (REDB) Printer control board (PRCB)
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). - - 2 Check the open/close operation of the upper right door. - - 3 Check the fusing unit, IHPU, MFPB and REDB for proper connection and correct or change as necessary. - - 4 Change TEMS1, TEMS2 or TEMS3 - - 5 Change fusing unit - - 6 Change IHPU - - 7 Change PRCB - - 8 Change REDB
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.