Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta bizhub C552DS — Trang 10/28

Code: C2254

Description: Color PC drum motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: Color PC drum motor (M16) Printer control board (PRCB)
Remedy: 1 Check the M16 connector for proper connection and correct as necessary. - - 2 Check the M16 connector for proper drive coupling and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 M16 operation check PRCB CN34-8 (REM) PRCB CN34-11 (LOCK) K-1 5 Change M16 - - 6 PRCB ICP13 conduction check - - 7 Change PRCB

Code: C2255

Description: Color developing motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Causes: Color developing motor (M17) Printer control board (PRCB)
Remedy: 1 Check the M17 connector for proper connection and correct as necessary. - - 2 Check the M17 connector for proper drive coupling and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 M17 operation check PRCB CN34-13 (REM) PRCB CN34-16 (LOCK) K-1 5 Change M17 - - 6 PRCB ICP13 conduction check - - 7 Change PRCB

Code: C2256

Description: Color developing motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: Color developing motor (M17) Printer control board (PRCB)
Remedy: 1 Check the M17 connector for proper connection and correct as necessary. - - 2 Check the M17 connector for proper drive coupling and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 M17 operation check PRCB CN34-13 (REM) PRCB CN34-16 (LOCK) K-1 5 Change M17 - - 6 PRCB ICP13 conduction check - - 7 Change PRCB

Code: C2257

Description: Cleaner motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Causes: Cleaner motor (M38) Printer control board (PRCB)
Remedy: 1 Check the M38 connector for proper connection and correct as necessary. - - 2 Check the M38 connector for proper drive coupling and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 M38 operation check PRCB CN2-3 (REM) PRCB CN2-6 (LOCK) K-11 5 Change M38 - - 6 PRCB ICP18 conduction check - - 7 Change PRCB

Code: C2258

Description: Cleaner motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: Cleaner motor (M38) Printer control board (PRCB)
Remedy: 1 Check the M38 connector for proper connection and correct as necessary. - - 2 Check the M38 connector for proper drive coupling and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 M38 operation check PRCB CN2-3 (REM) PRCB CN2-6 (LOCK) K-11 5 Change M38 - - 6 PRCB ICP18 conduction check - - 7 Change PRCB

Code: C2259

Description: K developing motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Causes: K developing motor (M19) Printer control board (PRCB)
Remedy: 1 Check the M19 connector for proper connection and correct as necessary. - - 2 Check the M19 connector for proper drive coupling and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 M19 operation check PRCB CN34-1 (REM) PRCB CN34-4 (LOCK) K-2 5 Change M19 - - 6 PRCB ICP14 conduction check - - 7 Change PRCB

Code: C225A

Description: K developing motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: K developing motor (M19) Printer control board (PRCB)
Remedy: 1 Check the M19 connector for proper connection and correct as necessary. - - 2 Check the M19 connector for proper drive coupling and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 M19 operation check PRCB CN34-1 (REM) PRCB CN34-4 (LOCK) K-2 5 Change M19 - - 6 PRCB ICP14 conduction check - - 7 Change PRCB

Code: C225B

Description: K PC drum motor’s failure to turn
• The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Causes: K PC drum motor (M18) Printer control board (PRCB)
Remedy: 1 Check the M18 connector for proper connection and correct as necessary. - - 2 Check the M18 connector for proper drive coupling and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 M18 operation check PRCB CN35-10 (REM) PRCB CN35-13 (LOCK) K-2 5 Change M18 - - 6 PRCB ICP14 conduction check - - 7 Change PRCB