Description: Finishing option cooling fan motor failure
Remedy:
Code: C1402
Description: FNS non-volatile memory failure
Remedy:
Code: C2101
Description: PC charge cleaning malfunction
• During backward movement of the cleaner, the charging cleaner home sensor is not blocked after a predetermined period of time has elapsed.
Remedy: 1 Check the imaging unit/K for proper connection and correct as necessary. 2 Check the M15 connector for proper connection and correct as necessary. 3 PS43 I/O check, sensor check PRCB CN8PRCB-8 (ON) C-12. 4 PS44 I/O check, sensor check PRCB CN8PRCB-11 (ON) C-13. 5 M15 operation check PRCB CN8PRCB-3 to 4 C-12. 6 Change imaging unit /K. 7 Change M15. 8 Change PRCB.
Code: C2151
Description: Secondary transfer roller pressure welding alienation
• The pressure welding alienation sensor doesn’t turn OFF (retracting) even after the lapse of a given period of time after the 2nd image transfer pressure retraction motor has started rotating during the 2nd image transfer roller is retracting. • The pressure welding alienation sensor doesn’t turn ON (pressuring) even after the lapse of a given period of time after the 2nd image transfer pressure retraction motor has started rotating during the 2nd image transfer roller is pressuring.
Remedy: 1 Check the M3 connector for proper connection and correct as necessary. 2 PS50 I/O check, sensor check PRCB CN36PRCB-9 (ON) K-4. 3 M3 operation check PRCB CN11PRCB-1 (REM) K-3. 4 Change M3. 5 Change PRCB.