Description: Transfer belt pressure welding alienation • At the completion of transfer belt pressure/ retraction operations, the pressure welding alienation sensor/K or the pressure welding alienation sensor/color is not in the status corresponding to each of the transfer belt pressure/retraction operations. See the table below. •Even after a predetermined period of time has elapsed since the transfer belt starts pressure/retraction operation, the pressure welding alienation sensor/K or the pressure welding alienation sensor/color is not in the status corresponding to each of the transfer belt pressure/retraction operations. See the table below. Operation Position Sensor status (K: Color) • Color and K retraction - K pressure • Color and K pressure - K K pressure ON (not blocked) :OFF (blocked) pressure • Color and K retraction - Color and K pressure • K pressure - Color and K pressure Color and K pressure ON (not blocked):ON (not blocked) • K pressure - Color and K retraction • Color and K pressure - Color and K Color and K retraction OFF (blocked): OFF (blocked) retraction
Causes: Pressure welding alienation sensor/K (PS51) Pressure welding alienation sensor/color (PS52) 1st image transfer pressure retraction motor (M21) Printer control board (PRCB)
Description: PC charge (C) malfunction • When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time. In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed. Then the trouble code corresponding to the IU color is displayed.
Causes: Imaging unit High voltage unit/1 (HV1) Printer control board (PRCB)
Remedy: 1 Check the imaging unit for proper connection and correct as necessary. - - 2 Check the HV1 connector for proper connection and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 Change IU - - 5 Change HV1 - - 6 Change PRCB
Code: C2161
Description: PC charge (M) malfunction • When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time. In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed. Then the trouble code corresponding to the IU color is displayed.
Causes: Imaging unit High voltage unit/1 (HV1) Printer control board (PRCB)
Remedy: 1 Check the imaging unit for proper connection and correct as necessary. - - 2 Check the HV1 connector for proper connection and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 Change IU - - 5 Change HV1 - - 6 Change PRCB
Code: C2162
Description: PC charge (Y) malfunction • When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time. In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed. Then the trouble code corresponding to the IU color is displayed.
Causes: Imaging unit High voltage unit/1 (HV1) Printer control board (PRCB)
Remedy: 1 Check the imaging unit for proper connection and correct as necessary. - - 2 Check the HV1 connector for proper connection and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 Change IU - - 5 Change HV1 - - 6 Change PRCB
Code: C2163
Description: PC charge (K) malfunction • When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time. In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed. Then the trouble code corresponding to the IU color is displayed.
Causes: Imaging unit High voltage unit/1 (HV1) Printer control board (PRCB)
Remedy: 1 Check the imaging unit for proper connection and correct as necessary. - - 2 Check the HV1 connector for proper connection and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 Change IU - - 5 Change HV1 - - 6 Change PRCB
Code: C2164
Description: PC charge malfunction • When electrostatic charge output is ON, electrostatic charge leak detection system continues to detect leaks for a predetermined period of time. In this case, C2164 is displayed at the first detection and then after the trouble is reset, a leak IU identification process is executed. Then the trouble code corresponding to the IU color is displayed.
Causes: Imaging unit High voltage unit/1 (HV1) Printer control board (PRCB)
Remedy: 1 Check the imaging unit for proper connection and correct as necessary. - - 2 Check the HV1 connector for proper connection and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 Change IU - - 5 Change HV1 - - 6 Change PRCB
Code: C2204
Description: Waste toner agitating motor’s failure to turn •The waste toner agitating motor lock sensor continues to be blocked or unblocked for a predetermined period of time when the motor is turning.
Causes: Waste toner agitating motor lock sensor (PS23) Waste toner agitating motor (M20) Printer control board (PRCB)
Remedy: 1 Clean the PS23 if it has toner or paper dust, etc. - - 2 Change the waste toner box. - - 3 Check the M20 connector for proper connection and correct as necessary. - - 4 Check the connector of motor for proper drive coupling and correct as necessary. - - 5 M20 operation check PRCB CN23-1 to 4 C-8 to 9 6 Change M20 - - 7 PRCB ICP3 conduction check - - 8 Change PRCB
Code: C2253
Description: Color PC drum motor’s failure to turn • The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Causes: Color PC drum motor (M16) Printer control board (PRCB)
Remedy: 1 Check the M16 connector for proper connection and correct as necessary. - - 2 Check the M16 connector for proper drive coupling and correct as necessary. - - 3 Check the PRCB connector for proper connection and correct as necessary. - - 4 M16 operation check PRCB CN34-8 (REM) PRCB CN34-11 (LOCK) K-1 5 Change M16 - - 6 PRCB ICP13 conduction check - - 7 Change PRCB