Description: Cyan TCR sensor failure • Alarm signals for a TCR sensor are detected more than the predetermined number of times. This detection is used for detecting disconnection of TCR sensor connector.
Causes: Imaging unit /C Imaging unit /M Imaging unit /Y Drum unit /K Printer control board (PRCB)
Remedy: 1 Reinstall imaging unit - - 2 Check the harness from imaging unit to PRCB for proper connection and correct as necessary. - - 3 Change imaging unit - - 4 PRCB ICP1 or ICP2 conduction check - - 5 Change PRCB
Code: C2562
Description: Magenta TCR sensor failure
Causes: Imaging unit /C Imaging unit /M Imaging unit /Y Drum unit /K Printer control board (PRCB)
Remedy: 1 Reinstall imaging unit - - 2 Check the harness from imaging unit to PRCB for proper connection and correct as necessary. - - 3 Change imaging unit - - 4 PRCB ICP1 or ICP2 conduction check - - 5 Change PRCB
Code: C2563
Description: Yellow TCR sensor failure
Causes: Imaging unit /C Imaging unit /M Imaging unit /Y Drum unit /K Printer control board (PRCB)
Remedy: 1 Reinstall imaging unit - - 2 Check the harness from imaging unit to PRCB for proper connection and correct as necessary. - - 3 Change imaging unit - - 4 PRCB ICP1 or ICP2 conduction check - - 5 Change PRCB
Code: C2564
Description: Black TCR sensor failure
Causes: Imaging unit /C Imaging unit /M Imaging unit /Y Drum unit /K Printer control board (PRCB)
Remedy: 1 Reinstall imaging unit - - 2 Check the harness from imaging unit to PRCB for proper connection and correct as necessary. - - 3 Change imaging unit - - 4 PRCB ICP1 or ICP2 conduction check - - 5 Change PRCB
Code: C2650
Description: Main backup media access error • Contact the responsible people of KMBT before taking some countermeasures.
Causes: Service EEPROM board (SV ERB) Printer control board (PRCB)
Remedy: 1 Check the connector (CN33) on PRCB, the connector (CN1) on SV ERB, and the harness between the boards for proper connection and correct as necessary. - - 2 Change PRCB 1. Turn OFF the main power switch and replace the current PRCB with a new one. (When using a PRCB of another machine in service, be sure to use a PRCB installed in the same model.) 2. Update the PRCB firmware. 3. After completing the firmware update, turn OFF and ON the main power switch and check to see that warm-up is started. Make sure that malfunction codes other than C2650 or improper IU/TC placement is not detected. 4. When the trouble cannot be solved, reinstall the removed PRCB to the original board. NOTE • When taking the above steps, check whether PRCB is defective or not without replacing the SV ERB. - - 3 Change SV ERB 1. Replace the current SV ERB with a new one. 2. Turn ON the main power switch and check to see that warm-up is started. (One minute is spent to prepare the new SV ERB for use. During the period, the control panel backlight stays off.) Make sure that malfunction codes other than C2650 or improper IU/TC placement is not detected. 3. Make the specified readjustments. - - 4 If the above actions do not solve the problem, contact KMBT.
Code: C2651
Description: EEPROM access error (IU C) •The re-written data, which has been read out, checked and founded as error, is read out again and found as error. • The error was found when reading out the counter value.
Causes: Imaging unit /C Imaging unit /M Imaging unit /Y Drum unit /K Printer control board (PRCB)
Remedy: 1 Clean the connection between the imaging unit and the machine if dirty - - 2 Reinstall imaging unit - - 3 Check the harness for proper connection and correct as necessary. - - 4 Change imaging unit - - 5 Change PRCB
Code: C2652
Description: EEPROM access error (IU M) •The re-written data, which has been read out, checked and founded as error, is read out again and found as error. • The error was found when reading out the counter value.
Causes: Imaging unit /C Imaging unit /M Imaging unit /Y Drum unit /K Printer control board (PRCB)
Remedy: 1 Clean the connection between the imaging unit and the machine if dirty - - 2 Reinstall imaging unit - - 3 Check the harness for proper connection and correct as necessary. - - 4 Change imaging unit - - 5 Change PRCB
Code: C2653
Description: EEPROM access error (IU Y) •The re-written data, which has been read out, checked and founded as error, is read out again and found as error. • The error was found when reading out the counter value.
Causes: Imaging unit /C Imaging unit /M Imaging unit /Y Drum unit /K Printer control board (PRCB)
Remedy: 1 Clean the connection between the imaging unit and the machine if dirty - - 2 Reinstall imaging unit - - 3 Check the harness for proper connection and correct as necessary. - - 4 Change imaging unit - - 5 Change PRCB