Description: PC motor/YMC’s failure to turn The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Causes: • PC motor/YMC (M16) • Printer control board (PRCB)
Remedy: 1 Check the connector between M16-PRCB CN22 for proper connection and correct as necessary. 2 Check the M16 connector for proper drive coupling and correct as necessary. 3 M16 operation check PRCB CN22-11 (LOCK) PRCB CN22-8 (REM) 15-K. 4 Replace M16. 5 PRCB ICP5 or ICP18 conduction check. 6 Replace PRCB.
Description: PC motor/YMC’s turning at abnormal timing The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: • PC motor/YMC motor (M16) • Printer control board (PRCB)
Remedy: 1 Check the connector between M16-PRCB CN22 for proper connection and correct as necessary. 2 Check the M16 connector for proper drive coupling and correct as necessary. 3 M16 operation check PRCB CN22-11 (LOCK) PRCB CN22-8 (REM) 15-K. 4 Replace M16. 5 PRCB ICP5 or ICP18 conduction check. 6 Replace PRCB.
Description: Developing motor/YMC’s failure to turn The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Causes: • Developing motor/YMC (M17) • Printer control board (PRCB)
Remedy: 1 Check the connector between M17-PRCB CN22 for proper connection and correct as necessary. 2 Check the M17 connector for proper drive coupling and correct as necessary. 3 M17 operation check PRCB CN22-13 to 17 15-K. 4 Replace M17. 5 PRCB ICP5 conduction check. 6 Replace PRCB.
Description: Developing motor/YMC’s turning at abnormal timingThe motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: • Developing motor/YMC (M17) • Printer control board (PRCB)
Remedy: 1 Check the connector between M17-PRCB CN22 for proper connection and correct as necessary. 2 Check the M17 connector for proper drive coupling and correct as necessary. 3 M17 operation check PRCB CN22-13 to 17 15-K. 4 Replace M17. 5 PRCB ICP5 conduction check. 6 Replace PRCB.
Description: Cleaning brush motor’s failure to turn The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Causes: • Cleaning brush motor (M38) • Printer control board (PRCB)
Remedy: 1 Check the connector between M38-PRCB CN39 for proper connection and correct as necessary. 2 Check the M38 connector for proper drive coupling and correct as necessary. 4 M38 operation check PRCB CN39-1 to 7 20-K. 5 Replace M38. 6 PRCB ICP8 conduction check. 7 Replace PRCB.
Description: Cleaning brush motor’s turning at abnormal timing The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: • Cleaning brush motor (M38) • Printer control board (PRCB)
Remedy: 1 Check the connector between M38-PRCB CN39 for proper connection and correct as necessary. 2 Check the M38 connector for proper drive coupling and correct as necessary. 4 M38 operation check PRCB CN39-1 to 7 20-K. 5 Replace M38. 6 PRCB ICP8 conduction check. 7 Replace PRCB.
Description: Developing motor/K’s failure to turn The motor lock signal remains HIGH for a predetermined continuous period of time while the motor is turning.
Causes: • Developing motor/K (M19) • Printer control board (PRCB)
Remedy: 1 Check the connector between M19-PRCB CN22 for proper connection and correct as necessary. 2 Check the M19 connector for proper drive coupling and correct as necessary. 3 M19 operation check PRCB CN22-1 to 5 16-K. 4 Replace M19. 5 PRCB ICP6 conduction check. 6 Replace PRCB.
Description: Developing motor/K’s turning at abnormal timing The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Causes: • Developing motor/K (M19) • Printer control board (PRCB)
Remedy: 1 Check the connector between M19-PRCB CN22 for proper connection and correct as necessary. 2 Check the M19 connector for proper drive coupling and correct as necessary. 3 M19 operation check PRCB CN22-1 to 5 16-K. 4 Replace M19. 5 PRCB ICP6 conduction check. 6 Replace PRCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.