Description: Transport motor’s turning at abnormal timing
• The motor lock signal remains LOW for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PRCB connector for proper connection and correct as necessary. 4 M1 operation check. 5 Change M1. 6 Change PRCB.
Description: Power supply cooling fan motor/1’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the FM8 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM8 operation check. 4 Change FM8. 5 Change DCPU. 6 Change PRCB.
Description: Exhaust fan motor’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the FM14 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM14 operation check. 4 Change FM14. 5 Change PRCB.
Description: Cooling fan motor/1’s failure to turn
• The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
Remedy: 1 Check the FM16 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM16 operation check. 4 Change FM16. 5 Change PRCB.
Description: Drive system home sensor malfunction
• The home position sensor (PS201) is defective or the exposure unit operates erratically.
Remedy: 1 Correct or change the scanner drive (wire, pulley, gear, belt) if it is faulty. 2 Correct the scanner motor set screw if loose. 3 Check the PS201, M201 and BCRUB connector for proper connection and correct as necessary. 4 PS201 I/O check, sensor check. 5 M201 operation check. 6 Change M201. 7 Change BCRUB.
Description: Other troubles of scanner
• The scan operation was terminated abnormally because of a reason except defined trouble.
Remedy: 1 Check the connectors between BCRUB and MFBUB for proper connection and correct as necessary. 2 Change BCRUB. 3 Change MFBUB. 4 Change exposure unitk.
Description: Image input time out
• The scan motion is not completed even after the lapse of a predetermined period of time because of a hardware failure or other reason.
Remedy: 1 Check the connectors between BCRUB and MFBUB for proper connection and correct as necessary. 2 Change BCRUB. 3 Change MFBUB. 4 Change exposure unit.
Description: CCD clamp/gain adjustment failure
• The automatic gain control fails to converge when the main unit is started or a scan motion is started (the exposure unit does not move to the white reference position, or the automatic gain control is not properly completed as a result of a hardware failure).
Remedy: 1 Correct the harness connection between CCDUB and BCRUB if faulty. 2 Check for possible extraneous light and correct as necessary. 3 Clean the lens, mirrors, CCD surface, and shading sheet if dirty 4 Correct reflective mirror of the scanner if faulty, or change scanner. 5 Change BCRUB. 6 Change exposure unit.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.