Code :
  • Code: C6753
  • Description: ASIC clock input error (back side)
    <When DF-701 is installed> When starting the machine, verification on reading and writing the predetermined value for image processing ASIC on dual scan image processing board (DSIPB) was conducted, and verification failure was detected.
  • Remedy: 1 Correct the harness connection between DF and DSIPB if faulty. 2 Correct the harness connection between DSIPB and MFPB if faulty. 3 Replace CIS. 4 Replace DSIPB. 5 Replace MFPB.
  • Code: C6754
  • Description: CIS clamp adjustment failure
    <When DF-701 is installed> After the gain adjustment is performed at the start-up, the CIS clamp adjustment value is too high or too low.
  • Remedy: 1 Correct the harness connection between CIS and DSIPB if faulty. 2 Correct the harness connection between CIS and CISPU if faulty. 3 Check for possible extraneous light and correct as necessary. 4 Clean the back side reading glass and the shading sheet if dirty. 5 Replace CIS. 6 Replace DSIPB. 7 Replace CISPU. 8 Replace MFPB.
  • Code: C6755
  • Description: CIS gain adjustment failure
    <When DF-701 is installed> After the gain adjustment is performed at the start-up, the peak value of the output data is lower than a given value.
  • Remedy: 1 Correct the harness connection between CIS and DSIPB if faulty. 2 Correct the harness connection between CIS and CISPU if faulty. 3 Check for possible extraneous light and correct as necessary. 4 Clean the back side reading glass and the shading sheet if dirty. 5 Replace CIS. 6 Replace DSIPB. 7 Replace CISPU. 8 Replace MFPB.
  • Code: C6756
  • Description: CCD power-supply voltage malfunction
    Power is not supplied to CCD after the lapse of a given period of time after the main power switch or sub power key is turned ON or the machine recovers from the sleep mode.
  • Remedy: 1 Correct the harness connection between CCDB and SCDB if faulty. 2 Correct the harness connection between SCDB and DCPU if faulty. 3 Replace CCDB. 4 Replace SCDB. 5 Replace DCPU.
  • Code: C6901
  • Description: DSC board mount failure 1
    When MFP detects that DSC board/1 (front side) is not properly installed.
  • Remedy: 1 Correct the harness connection of DSCB/1 if faulty. 2 Replace DSCB/1. 3 Replace MFPB
  • Code: C6902
  • Description: DSC board bus check NG1-1
    When DSC bus check (front side) detects an error.
  • Remedy: 1 Correct the harness connection of DSCB/1 if faulty. 2 Replace DSCB/1. 3 Replace MFPB
  • Code: C6903
  • Description: DSC board bus check NG1-2
    When DSC bus check (front side) detects an error.
  • Remedy: 1 Correct the harness connection of DSCB/1 if faulty. 2 Replace DSCB/1. 3 Replace MFPB
  • Code: C6911
  • Description: DSC board mount failure 2
    <When DF-701 is installed> When MFP detects that DSC board/2 (back side) is not properly installed.
  • Remedy: 1 Correct the harness connection of DSCB/2 if faulty. 2 Correct the harness connection of DSIPB if faulty. 3 Replace DSCB/2. 4 Replace DSIPB. 5 Replace MFPB.