Description: An error detection signal of FM5 is detected continuously for a specified period of time while the paper cooling fan motor /Rr (FM5) is ON.
Causes: • Paper cooling fan motor /Rr (FM5) • LS control board (LSCB)
Remedy: 1. Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: LS-505: 5-A) 3. Replace FM5. 4. Replace LSCB.
Code: C-1306
Description: An error detection signal is detected continuously for a specified period of time while the paper cooling fan motor /Fr (FM1) is ON.
Causes: • Paper cooling fan motor /Fr (FM1) • LS control board (LSCB)
Remedy: 1. Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: LS-505: 4-A) 3. Replace FM1. 4. Replace LSCB.
Code: C-1307
Description: An error detection signal is detected continuously for a specified period of time while the paper cooling fan motor/1 (FM2) is ON.
Causes: • Paper cooling fan motor /1 (FM2) • LS control board (LSCB)
Remedy: 1. Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: LS-505: 6-H) 3. Replace FM2 or FM6. 4. Replace LSCB.
Code: C-1308
Description: An error detection signal is detected continuously for a specified period of time while the paper cooling fan motor /Mi (FM3) is ON.
Causes: • Paper cooling fan motor /Mi (FM3) • LS control board (LSCB)
Remedy: 1. Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: LS-505: 5-A) 3. Replace FM3 4. Replace LSCB.
Code: C-1309
Description: An error detection signal of FM4 is detected continuously for a specified period of time while the motor cooling fan motor (FM4) is ON.
Causes: • Motor cooling fan motor • LS control board (LSCB)
Remedy: 1. Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: LS-505: 7-H) 3. Replace FM4 4. Replace LSCB.
Code: C-1310
Description: An error detection signal of FM5 is detected continuously for a specified period of time while the paper cooling fan motor /Rr (FM5) is ON.
Causes: • Paper cooling fan motor /Rr (FM5) • LS control board (LSCB)
Remedy: 1. Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: LS-505: 5-A) 3. Replace FM5. 4. Replace LSCB.
Code: C-1311
Description: A rotation error detection signal is detected continuously for specified period of time while the scraps removal fan motor (FM1) is started or driving.
Causes: • Scraps removal fan motor (FM1) • SD control board (SDCB) • SD drive board (SDDB) DIPSW7-3
Remedy: 1. Check the connector connection and the wiring between SDDB and the fan, and repair it if any abnormality. 2. Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. 3. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: SD-506: 26-D) 4. Replace FM1. 5. Replace SDDB. 6. Replace SDCB.
Code: C-1316
Description: An error detection signal is detected continuously for a specified period of time while the paper cooling fan motor /Fr (FM1) is ON.
Causes: • Paper cooling fan motor /Fr (FM1) • LS control board (LSCB)
Remedy: 1. Check the connector connection and the wiring between LSCB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: LS-505: 4-A) 3. Replace FM1. 4. Replace LSCB.