Description: Drive communication reception error detection abnormality 2.
Causes: • Printer control board (PRCB: main body) • PF drive board (PFUDB: PF-703/706)
Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring between PRCB and PFUDB, and repair it if any abnormality. 3. Check the connector connection on PRCB and PFUDB, and repair it if any abnormality. 4. Replace PFUDB. 5. Replace PRCB
Code: C-0011
Description: Drive communication reception error detection abnormality 8.
Causes: • Printer control board (PRCB: main body) • PF drive board (PFUDB: PF-703/706)
Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring between PRCB and PFUDB, and repair it if any abnormality. 3. Check the connector connection on PRCB and PFUDB, and repair it if any abnormality. 4. Replace PFUDB. 5. Replace PRCB.
Code: C-0012
Description: Drive communication reception error detection abnormality 9.
Causes: • Printer control board (PRCB: main body) • PF drive board (PFUDB: PF-703/706)
Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring between PRCB and PFUDB, and repair it if any abnormality. 3. Check the connector connection on PRCB and PFUDB, and repair it if any abnormality. 4. Replace PFUDB. 5. Replace PRCB.
Code: C-0020
Description: ADU drive serial input abnormality 1. In the initial communication check between the printer control board (PRCB) and the ADU drive board (ADUDB) after the power ON, a serial data is not received.
Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring between PRCB and ADUDB, and repair it if any abnormality 3. Check the connector connection on PRCB and ADUDB, and repair it if any abnormality 4. Replace ADUDB 5. Replace PRCB.
Code: C-0021
Description: ADU drive serial input abnormality 2. In the initial communication check between the printer control board (PRCB) and the ADU drive board (ADUDB) after the power ON, a serial data is not received.
Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring between PRCB and ADUDB, and repair it if any abnormality 3. Check the connector connection on PRCB and ADUDB, and repair it if any abnormality 4. Replace ADUDB 5. Replace PRCB.
Code: C-0022
Description: ADU drive serial input abnormality 3. In the initial communication check between the printer control board (PRCB) and the ADU drive board (ADUDB) after the power ON, a serial data is not received.
Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring between PRCB and ADUDB, and repair it if any abnormality 3. Check the connector connection on PRCB and ADUDB, and repair it if any abnormality 4. Replace ADUDB 5. Replace PRCB.
Code: C-0023
Description: Drive communication reception error detection abnormality 0.
Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring between PRCB and ADUDB, and repair it if any abnormality 3. Check the connector connection on PRCB and ADUDB, and repair it if any abnormality 4. Replace ADUDB 5. Replace PRCB.
Code: C-0024
Description: Drive communication reception error detection abnormality 7.
Remedy: 1. After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. 2. Check the connector connection and the wiring between PRCB and ADUDB, and repair it if any abnormality 3. Check the connector connection on PRCB and ADUDB, and repair it if any abnormality 4. Replace ADUDB 5. Replace PRCB.