Các lỗi thường gặp

Code :
  • Code: C-0520
  • Description: 1st tandem PF-703 paper suction fan /1 (FM14) rotation abnormality. The FM14EM error detection signal is detected twice in succession within a specified period of time after FM14 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
  • Causes: • Paper suction fan /2 (FM14: PF-703) • PF drive board (PFUDB: PF-703)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 14-L) 3. Replace FM14. 4. Replace PFUDB.
  • Code: C-0521
  • Description: 1st tandem PF-703 paper suction fan /3 (FM16) power abnormality. The FM16 EM error detection of FM16 is detected twice in succession within a specified period of time after FM16 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
  • Causes: • Paper suction fan /4 (FM16: PF-703) • PF drive board (PFUDB: PF-703)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 16-L) 3. Replace FM16 and PFUDB.
  • Code: C-0522
  • Description: 1st tandem PF-703 paper suction fan /3 (FM16) rotation abnormality. The FM16EM error detection signal is detected twice in succession within a specified period of time after FM16 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
  • Causes: • Paper suction fan /4 (FM16: PF-703) • PF drive board (PFUDB: PF-703)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 16-L) 3. Replace FM16. 4. Replace PFUDB.
  • Code: C-0523
  • Description: 1st tandem PF-703 paper suction fan /5 (FM18) power abnormality. The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
  • Causes: • Paper suction fan /6 (FM18: PF-703) • PF drive board (PFUDB: PF-703)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-L) 3. Replace FM18 and PFUDB.
  • Code: C-0524
  • Description: 1st tandem PF-703 paper suction fan /5 (FM18) rotation abnormality. The FM18EM error detection signal is detected twice in succession within a specified period of time after FM18 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
  • Causes: • Paper suction fan /6 (FM18: PF-703) • PF drive board (PFUDB: PF-703)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 19-L) 3. Replace FM18. 4. Replace PFUDB.
  • Code: C-0525
  • Description: 2nd tandem PF-703 paper leading edge separation fan /Fr1 (FM3) power abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
  • Causes: • Paper leading edge separation fan /Fr1 (FM3: PF-703) • PF drive board (PFUDB: PF-703)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 6-F) 3. Replace FM3 and PFUDB.
  • Code: C-0526
  • Description: 2nd tandem PF-703 paper leading edge separation fan /Fr1 (FM3) rotation abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
  • Causes: • Paper leading edge separation fan /Fr1 (FM3: PF-703) • PF drive board (PFUDB: PF-703)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 6-F) 3. Replace FM3. 4. Replace PFUDB.
  • Code: C-0527
  • Description: 2nd tandem PF-703 paper leading edge separation fan /Fr2 (FM7) power abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
  • Causes: • Paper leading edge separation fan /Fr2 (FM7: PF-703) • PF drive board (PFUDB: PF-703)
  • Remedy: 1. Check the connector connection and the wiring between PFUDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: PF-703: 11-F) 3. Replace FM7 and PFUDB.