Code: C-1521

Description: The driven arm /Rt swing operation start has not been completed within a specified period of time after the cover paper conveyance arm motor /Rt (M43) turns ON
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Cover paper conveyance arm motor / Rt (M43) DIPSW7-6
Remedy: 1. Check the cover paper conveyance section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:PB-503:12-D) 5. Replace M43. 6. Replace PBDB1. 7. Replace PBCB.

Code: C-1522

Description: The driven arm /Lt swing operation start has not been completed within a specified period of time after the cover paper conveyance arm motor /Lt (M44) turns ON
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Cover paper conveyance arm motor / Lt (M44) DIPSW7-6
Remedy: 1. Check the cover paper conveyance section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PB-503: 13-D) 5. Replace M44. 6. Replace PBDB1. 7. Replace PBCB.

Code: C-1523

Description: The cover paper conveyance start has not been completed within a specified period of time after cover paper conveyance motor (M45) turns ON.
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Cover paper conveyance motor (M45) DIPSW7-6
Remedy: 1. Check the cover paper conveyance section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PB-503: 13-D) 5. Replace M45. 6. Replace PBDB1. 7. Replace PBCB.

Code: C-1524

Description: The cover paper table up or down movement has not been completed within a specified period of time after the cover paper table up down motor /Fr (M46) turns ON.
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Cover paper table up down motor /Fr (M46) DIPSW7-6
Remedy: 1. Check the cover paper table up down section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:PB-503: 11-D) 5. Replace M46. 6. Replace PBDB1. 7. Replace PBCB.

Code: C-1525

Description: The cover paper table up or down movement has not been completed within a specified period of time after the cover paper table up down motor /Rr (M47) turns ON.
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Cover paper table up down motor /Rr (M47) DIPSW7-6
Remedy: 1. Check the cover paper table up down section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:PB-503: 11-D) 5. Replace M47. 6. Replace PBDB1. 7. Replace PBCB.

Code: C-1526

Description: The movement of the cover paper folding plate / Rt has not been completed within a specified period of time after the cover paper folding motor /Rt (M48) turns ON.
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Cover paper folding motor /Rt (M48) DIPSW7-6
Remedy: 1. Check the cover paper folding section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:PB-503: 14-D) 5. Replace M48. 6. Replace PBDB1. 7. Replace PBCB.

Code: C-1527

Description: The movement of the cover paper folding plate / Lt has not been completed within a specified period of time after the cover paper folding motor /Lt (M49) turns ON.
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Cover paper folding motor /Lt (M49) DIPSW7-6
Remedy: 1. Check the cover paper folding section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:PB-503: 14-D) 5. Replace M49. 6. Replace PBDB1. 7. Replace PBCB.

Code: C-1528

Description: The trimming of the cover paper has not been completed within a specified period of time after the cutter motor (M50) turns ON.
Causes: • PB control board (PBCB) • PB drive board (PBDB) • Cutter motor (M50) DIPSW7-6
Remedy: 1. Check the trimmer section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:PB-503: 14-D) 5. Replace M50. 6. Replace PBDB1. 7. Replace PBCB.