Description: Original skew sensor /Rr (PS311) abnormality.
Causes: • Original skew sensor /Rr (PS311: DF-615/616) • DF control board (DFCB: DF-615/616) DIPSW18-4
Remedy: 1. Check the connector connection and the wiring between DFCB and the sensor, and repair it if any abnormality. 2. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: DF-615/616: 2-E) 3. Replace PS311. 4. Replace DFCB
Description: Original registration sensor /Rt (PS318) abnormality.(DF-615 only)
Causes: • Original registration sensor /Rt (PS318: DF-615) • DF control board (DFCB: DF-615) DIPSW18-4
Remedy: 1. Check the connector connection and the wiring between DFCB and the sensor, and repair it if any abnormality. 2. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: DF-615: 1-C) 3. Replace PS318. 4. Replace DFCB
Remedy: 1. Check the connector connection and the wiring between DFCB and the sensor, and repair it if any abnormality. 2. Check the sensor to see LED emission and light-receiving path, and repair/replace it if any abnormality. (Wiring diagram: DF-615: 1-F, 1-E) 3. Replace PS319 and PS320. 4. Replace DFCB
Remedy: 1. Check the connector connection and the wiring between DFCB and the sensor, and repair it if any abnormality. 2. Check the sensor to see LED emission and light-receiving path, and repair/replace it if any abnormality. (Wiring diagram: DF-615: 1-F, 2-E) 3. Replace PS321 and PS322. 4. Replace DFCB
Description: Multi feed detection boards /S (MFDBS) and /R (MFDBR) abnormality(DF-615 only)
Causes: • Multi feed detection boards /S (MFDBS: DF-615) • Multi feed detection boards /R (MFDBR: DF-615) • DF control board (DFCB: DF-615) DIPSW18-4
Remedy: 1. Check the connector connection and the wiring between DFCB and the multi-feed detection board, and repair it if any abnormality. 2. Check the multi-feed detection board to see emission and receiving path, and repair/replace it if any abnormality. (Wiring diagram: DF-615: 1-B, 7-A) 3. Replace MFDBS or MFDBR. 4. Replace DFCB
Description: Transfer error to the main body image memory
Causes: • IC board (ICB) • PCI relay board (PCIRB) • Overall control board (OACB)
Remedy: 1. Check the connector connection and the wiring between ICB and PCIRB/between PCIRB and OACB, and repair it if any abnormality. 2. Replace ICB. 3. Replace PCIRB. 4. Replace OACB.
Causes: • IC board (ICB) • PCI relay board (PCIRB) • Hard disk /2 (HDD2)
Remedy: 1. Check the connector connection and the wiring between ICB and HDD2/between PCIRB and HDD2, and repair it if any abnormality. 2. Format HDD2. 3. Replace HDD2. 4. Replace PCIRB. 5. Replace ICB.
Description: IC cooling fan (FM39) lock abnormality.
Causes: • IC cooling fan (FM39) • IC board (ICB)
Remedy: 1. Check the connector connection and the wiring between ICB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair/replace it if any abnormality. (Wiring diagram: Main body (4/4): 22-E) 3. Replace FM39. 4. Replace ICB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.