Description: The blowout of a fuse for the paper feed assist fan /Rr2 (FM23) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM23 EM signal a specified period of time after the FM23 is turned ON. This abnormal condition recurs even a specified period of time after the FM23 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal.
Causes: Paper feed assist fan /Rr2 (FM23) Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC32-32
Description: The rotation of the paper feed assist fan /Rr2 (FM23) is checked. An abnormal condition occurs with the FM23 EM signal a specified period of time after the FM23 is turned ON. This abnormal condition recurs even a specified period of time after the FM23 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected.
Causes: Paper feed assist fan /Rr2 (FM23) Printer control board (PRCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC32-33
Description: The rotation of the paper feed assist fan /Fr1 (FM41) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM41 EM signal a specified period of time after the FM41 is turned ON. This abnormal condition recurs even a specified period of time after the FM41 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS/ 2)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC32-34
Description: The blowout of a fuse for the paper feed assist fan /Fr1 (FM41) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM41 EM signal a specified period of time after the FM41 is turned ON. This abnormal condition recurs even a specified period of time after the FM41 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal.
Causes: Paper feed assist fan /Fr1 (FM41) PF drive board (PFUDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC32-35
Description: The rotation of the paper feed assist fan /Fr1 (FM41) is checked. An abnormal condition occurs with the FM41 EM signal a specified period of time after the FM41 is turned ON. This abnormal condition recurs even a specified period of time after the FM41 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected.
Causes: Paper feed assist fan /Fr1 (FM41) PF drive board (PFUDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC32-36
Description: The rotation of the paper feed assist fan /Rr1 (FM42) is checked, and the 24V power source is also checked. An abnormal condition occurs with the FM42 EM signal a specified period of time after the FM42 is turned ON. This abnormal condition recurs even a specified period of time after the FM42 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
Causes: DC power supply /2 (DCPS/ 2)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC32-37
Description: The blowout of a fuse for the paper feed assist fan /Rr1 (FM42) in the printer control board (PRCB) is checked. An abnormal condition occurs with the FM42 EM signal a specified period of time after the FM42 is turned ON. This abnormal condition recurs even a specified period of time after the FM42 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected with the 24V normal.
Causes: Paper feed assist fan /Rr1 (FM42) PF drive board (PFUDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Code: SC32-38
Description: The rotation of the paper feed assist fan /Rr1 (FM42) is checked. An abnormal condition occurs with the FM42 EM signal a specified period of time after the FM42 is turned ON. This abnormal condition recurs even a specified period of time after the FM42 is turned OFF and then turned ON, and an error detection signal (24V cut off/blowout of a fuse) is not detected.
Causes: Paper feed assist fan /Rr1 (FM42) PF drive board (PFUDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).