Mã lỗi Konica-Minolta bizhub Pro 1050eP — Trang 41/42
Description: The intermediate conveyance motor (M3) detects an error detection signal for a specified period of time in succession.
Causes: Intermediate conveyance motor (M3) Punch drive board (PDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Description: The PI conveyance motor (M7) detects an error detection signal for a specified period of time in succession.
Causes: PI conveyance motor (M7) PI drive board (PIDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Description: The main tray paper exit motor (M17) detects an error detection signal for a specified period of time in succession.
Causes: Main tray paper exit motor (M17) Punch drive board (PDB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Description: Resending of communication data due to an error is not available.
Causes: Main body I/F wiring harness
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Description: When non-volatile memory is being accessed, no response is obtained for a specified period of time.
Causes: FD control board (FDCB)
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Description: When the FD is unready, a signal to start operations is received from the main body.
Causes: Irregular operations. Recovery by turning the power ON and OFF.
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Description: The communication message queue between the tasks in the FD is full.
Causes: Irregular operations. Recovery by turning the power ON and OFF.
Remedy: The main body stops immediately to turn OFF the RL1 (main).
Description: The ISW information is not written. Or, the ROM check of the FD results in an error.
Causes: FD control board (FDCB) Wiring harness between the FDCB and the main bo
Remedy: The main body stops immediately to turn OFF the RL1 (main).