Các lỗi thường gặp

Code :
  • Code: SC50-07
  • Description: Drive communication reception error detection abnormality
  • Causes: Printer control board (PRCB)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC50-08
  • Description: Drive communication reception error detection abnormality.
  • Causes: Printer control board (PRCB)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC50-10
  • Description: Initial communication check between the IC board (ICB)/printer control board (PRCB). Image processing board communication connection abnormality. An initial data is not received from the image processing board (IPB) within a specified period of time after the power is turned ON.
  • Causes: Overall control board (OACB) Printer control board (PRCB)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC51-01
  • Description: Drive communication reception error detection abnormality.
  • Causes: Overall control board (OACB) Printer control board (PRCB)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC51-02
  • Description: Drive communication reception error detection abnormality.
  • Causes: Printer control board (PRCB) PF drive board (PFUDB)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC51-03
  • Description: Drive communication reception error detection abnormality.
  • Causes: Printer control board (PRCB) PF drive board (PFUDB)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC52-01
  • Description: The rotation of the cooling fan /1 (FM1) is checked, and +24V power source is also checked. An abnormal condition occurs with the FM1 EM signal a specified period of time after the FM1 turns ON. This abnormal condition recurs even a specified period of time after the FM1 is turned OFF and then turned ON, and an error detection signal (24V cut off) is detected.
  • Causes: DC power supply /2 (DCPS/ 2)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
  • Code: SC52-02
  • Description: The blowout of a fuse for the cooling fan /1 (FM1) in the AC drive board (ACDB) is checked. An abnormal condition occurs with the FM1 EM signal a specified period of time after the FM1 turns ON. This abnormal condition recurs even a specified period of time after the FM1 is turned OFF and then turned ON, and an error detection signal (blowout of a fuse) is detected. At this time, an error detection signal (24V cut off) is not detected.
  • Causes: AC drive board (ACDB) Cooling fan /1 (FM1) Printer control board (PRCB)
  • Remedy: The main body stops immediately to turn OFF the RL1 (main).
‹ First  < 25 26 27 28 29 30 31 >  Last ›