Description: Suction fan (FM32) power abnormality. The FM32EM error detection signal is detected twice in succession within a specified period of time after FM32 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: Suction fan (FM32) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 3-L 3 Replace FM32 and PRCB at a time.
Description: Suction fan (FM32) rotation abnormality. The FM32EM error detection signal is detected twice in succession within a specified period of time after FM32 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: Suction fan (FM32) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 3-L 3 Replace FM32. - 4 Replace PRCB.
Description: The fall-off of the erase lamp (EL) CN is detected. When turning ON the power, an error detection signal (fall-off) is detected a specified period of time after the fall-off detection control signal of the EL CN turns ON.
Causes: Erase lamp (EL) Printer control board (PRCB)
Remedy: 1 Check the EL section, and clean/repair it if any abnormality. 16-F 2 Check the connector connection and the wiring between PRCB and EL, and repair it if any abnormality. - 3 Replace EL. - 4 Replace PRCB.
Description: Drum temperature sensor wiring harness breakage. When the change in temperature of the drum temperature sensor (TH5) is less than -2°C a specified period of time after the main power switch (SW1) turns ON to start the control of the dehumidification heater /1 (HTR1) and the drum temperature is below 10°C after 1minute.
Causes: Drum temperature sensor (TH5) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and TH5, and repair it if any abnormality. - 2 Check the TH5, and repair/replace it if any abnormality. 17-F 3 Replace TH5. - 4 Replace PRCB.
Description: Drum temperature sensor wiring harness breakage. When the main power switch (SW1) turns ON with the fusing temperature below 50°C, the detected temperature of the drum temperature sensor (TH5) is more than 52°C, and when the detected temperature is above 52°C after a specified period of time.
Causes: Drum temperature sensor (TH5) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and TH5, and repair it if any abnormality. - 2 Check the TH5, and repair/replace it if any abnormality. 17-F 3 Replace TH5. - 4 Replace PRCB.
Description: TCR sensor (TCRS) output abnormality 1. The TCRS output is detected more than 3.0V (153step) in printing.
Causes: TCR sensor (TCRS) Printer control board (PRCB)
Remedy: 1 Check TCRS, and clean/repair it if there is sensor dirt or any abnormality. 18-F 2 Check the developing section, and clean/repair it if there is sensor dirt or any abnormality. - 3 Check the connector connection and the wiring between PRCB and TCRS, and repair it if any abnormality. - 4 Replace TCRS. - 5 Replace PRCB.
Description: TCR sensor (TCRS) output abnormality 2. The TCRS output is detected more than 0.5V (25step) in printing.
Causes: TCR sensor (TCRS) Printer control board (PRCB)
Remedy: 1 Check TCRS, and clean/repair it if there is sensor dirt or any abnormality. 18-F 2 Check the developing section, and clean/repair it if there is sensor dirt or any abnormality. - 3 Check the connector connection and the wiring between PRCB and TCRS, and repair it if any abnormality. - 4 Replace TCRS. - 5 Replace PRCB.
Description: TCR sensor (TCRS) output abnormality 3. • The mode does not return from the toner supply mode to the normal mode within a specified period of time after the toner automatic supply is executed in printing. • The TCRS output is detected more than 2.6V (132step).
Causes: TCR sensor (TCRS) Printer control board (PRCB)
Remedy: 1 Check TCRS, and clean/repair it if there is sensor dirt or any abnormality. 18-F 2 Check the developing section, and clean/repair it if there is sensor dirt or any abnormality. - 3 Check the connector connection and the wiring between PRCB and TCRS, and repair it if any abnormality. - 4 Replace TCRS. - 5 Replace PRCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.