Các lỗi thường gặp

Code :
  • Code: C-A009
  • Description: Controller memory abnormality.
  • Causes: DIMM (DIMM) IC board (ICB)
  • Remedy: 1 Check DIMM on ICB, and reinstall it if any abnormality. 21-D 2 Replace DIMM. - 3 Replace ICB.
  • Code: C-A101
  • Description: Controller initial communication abnormality.
  • Causes: IC board (ICB) PCI relay board (PCIRB) Overall control board (OACB)
  • Remedy: 1 Check the connector connection and the wiring between ICB and PCIRB/between PCIRB and OACB, and repair it if any abnormality. - 2 Replace ICB. - 3 Replace PCIRB. - 4 Replace OACB.
  • Code: C-C101
  • Description: Initial communication error between the overall control board (OACB) and the printer control board (PRCB). No response is returned from PRCB even after a specified period of time after the main power switch (SW1) and the sub power switch (SW2) turn ON. Or ISW information is not written on PRCB.
  • Causes: Printer control board (PRCB) Overall control board (OACB)
  • Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between PRCB and OACB, and repair it if any abnormality. - 3 Replace PRCB. - 4 Replace OACB.
  • Code: C-C102
  • Description: Communication error between the overall control board (OACB) and the printer control board (PRCB). Communication error from PRCB is detected. Or transmission is not completed.
  • Causes: Printer control board (PRCB) Overall control board (OACB)
  • Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between PRCB and OACB, and repair it if any abnormality. - 3 Replace PRCB. - 4 Replace OACB.
  • Code: C-C103
  • Description: Communication error between the overall control board (OACB) and the operation board (OB1). Communication error from OB1 is detected. Or transmission is not completed.
  • Causes: Operation board /1 (OB1) Overall control board (OACB)
  • Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring between OB1 and OACB, and repair it if any abnormality. 9-C 3 Check the connector connection and the wiring of the operation panel, and repair it if any abnormality. - 4 Replace OB1. - 5 Replace OACB.
  • Code: C-C104
  • Description: ISW write abnormality 1 of the printer control board.
  • Causes: IC board (ICB) PCI relay board (PCIRB) Overall control board (OACB) Printer control board (PRCB)
  • Remedy: 1 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ICB and PRCB, and repair it if any abnormality. 21-C 3 Reinstalling firmware - 4 Replace PRCB.
  • Code: C-C105
  • Description: ISW write abnormality 2 of the printer control board.
  • Causes: IC board (ICB) PCI relay board (PCIRB) Overall control board (OACB) Printer control board (PRCB)
  • Remedy: 1 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ICB and PRCB, and repair it if any abnormality. 21-C 3 Reinstalling firmware - 4 Replace PRCB.
  • Code: C-C106
  • Description: ISW time out error. No normal header is transmitted within a specified period of time after ISW is started.
  • Causes: IC board (ICB) PCI relay board (PCIRB) Overall control board (OACB)
  • Remedy: 1 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ICB and OACB, and repair it if any abnormality. 21-C 3 Reinstalling firmware - 4 Replace OACB.