Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Konica-Minolta Di151 — Trang 2/2

Code: C1200

Description: System memory failure
A memory test error is detected during the power-on initialization procedure.
Remedy: 1. Reset the malfunction. 2. If the malfunction is detected again, check the Control Board and Memory Board for proper connections. 3. If connections are okay, change the Control Board and/or Memory Board.

Code: C1300

Description: Polygon Motor malfunction
• During the period 6 s after the Polygon Motor has been energized, a cluster of 56 or more SOS signals output for a 20 ms period is detected five consecutive times. • After the lapse of 6 s after the Polygon Motor has been energized, a cluster of below 43 or above 56 SOS signals output for a 20 ms period is detected five consecutive times. • No SOS signal is detected during the period from the start of laser emission to the deenergization of the Polygon Motor.
Remedy: 1. Reset the malfunction. 2. If the malfunction is detected again, check the harness between, and PJ connections on, the PH Unit and Master Board. 3. If connections are okay, change the PH Unit and Master Board.

Code: C133B

Description: Option communications error
The Controller Board is not detected within 5 s after the start of a print cycle.
Remedy: 1. Reset the malfunction. 2. If the malfunction is detected again, check the Control Board and the controller board. 3. If connections are okay, change the Control Board and the controller board.

Code: C13F0

Description: SOS detection failure
• During the period 6 s after the Polygon Motor has been energized, a cluster of 56 or more SOS signals output for a 20 ms period is detected five consecutive times. • After the lapse of 6 s after the Polygon Motor has been energized, a cluster of below 43 or above 56 SOS signals output for a 20 ms period is detected five consecutive times. • No SOS signal is detected during the period from the start of laser emission to the deenergization of the Polygon Motor.
Remedy: 1. Reset the malfunction. 2. If the malfunction is detected again, check the harness between, and PJ connections on, the PH Unit and Master Board. 3. If connections are okay, change the PH Unit and Master Board.

Code: C1468

Description: Hardware (EEPROM) malfunction
An EEPROM read/write error occurs during the power-on initialization procedure.
Remedy: 1. Run “FA” of Function. 2. If it has not been checked okay (“FF” appears on the display), change the EEPROM on the Control Board. If it has been checked okay (“00” appears on the display), change the Control Board itself.

Code: C14A3

Description: Exposure Lamp malfunction
The intensity level of the Exposure Lamp does not stabilize within a given period of time.
Remedy: 1 Proper connections between the Scanner, Scanner Interface Board, and Control Board YES Change Scanner Interface Board. Change Control Board. Change Scanner. NO Correct connections.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie