Code: C1450

Description: Sequence trouble timeout
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, check the cables, timing belt, and other drive transmission mechanism from the Scanner Motor to the Scanner. 3. If step 2 has been checked okay, change Image Processing Board.

Code: C1461

Description: Serial GA1 failure
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.

Code: C1462

Description: Serial GA2 failure
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.

Code: C1470

Description: Module-to-module communication (CCM-EVM)
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.

Code: C1471

Description: Module-to-module communication (EVM-SQM)
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.

Code: C1472

Description: Module-to-module communication (EVM-AMM)
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.

Code: C1499

Description: IR cooling fan malfunction
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, check CN152 of IR Cooling Fan Motor and PJ4IC of SCP Board for proper connection. 3. If the connections are okay, change motor or SCP Board.

Code: C18XX

Description: SCSI communications unit failure
Remedy: 1. Reset the malfunction. 2. If the same malfunction persists, change Image Processing Board.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie