Các lỗi thường gặp

Code :
  • Code: E46-23
  • Description: Image control abnormality
    During image read, SVV is not turned OFF within the specified time and therefore preparation for next page scanning cannot be started.
  • Causes: PRCB (printer control board) ICB (image control board) ICB program
  • Code: E46-24
  • Description: Image control abnormality
    Shading correction error (GA error)
  • Causes: ICB (image control board) ICB program
  • Code: E46-25
  • Description: Image control abnormality
    AOC/AGC error • The light blocking cover and lens cover are removed from the scanner section. • The A/D converter board connector is disconnected. • The power cable of A/D converter board is disconnected. • The IC protector on the A/D converter board is blown out. • The exposure lamp intensity is excessive. • The exposure lamp does not light.
  • Causes: ADB (A/D conversion board) L1 (exposure lamp)
  • Code: E46-26
  • Description: Image control abnormality
    Correction data saved on a resolution basis is not found.
  • Causes: ICB (image control board)
  • Code: E46-27
  • Description: Image control abnormality
    The density correction γ curve cannot be generated properly.
  • Causes: ICB (image control board)
  • Code: E46-29
  • Description: Image control abnormality
    Calibration start error.
  • Causes: ICB (image control board) ICB program
  • Code: E46-30
  • Description: Image control abnormality
    Calibration end error
  • Causes: ICB (image control board) ICB program
  • Code: E46-31
  • Description: Image control abnormality
    An attempt was made to perform APC initial sampling before completion of MPC.
  • Causes: ICB (image control board) ICB program