Description: Mechanical Control Board malfunction
• Communications with the M/C expansion IO G/A (IC on the Mechanical Control Board) are not properly carried out.
Remedy: 1 Check the PWB-A connector for proper connection and correct as necessary. 2 Change PWB-A.
Description: Main Motor malfunction
• The Motor Lock signal remains HIGH for a predetermined consecutive period of time while the Main Motor remains energized. • The Motor Lock signal remains LOW for a predetermined consecutive period of time while the Main Motor remains deenergized.
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M1 operation check. PWB-A PJ8A-5 (REM) PWB-A PJ8A-8 (LOCK) 2-G-H 5 Change PWB-A. 6 Change PU.
Description: Ventilation Fan Motor malfunction
• The Fan Motor Lock signal remains HIGH for a predetermined consecutive period of time while the Ventilation Fan Motor remains energized.
Remedy: 1 Check the M6 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M6 operation check. PWB-A PJ10A-1 (REM) PWB-A PJ10A-3 (LOCK) 2-H. 5 Change PWB-A. 6 Change PU.
Description: Power Supply Cooling Fan Motor malfunction
• The Fan Motor Lock signal remains HIGH for a predetermined consecutive period of time while the Power Supply Cooling Fan Motor remains energized.
Remedy: 1 Check the M4 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 Check the PWB-A connector for proper connection and correct as necessary. 4 M4 operation check. PWB-A PJ4A-1 (REM) PWB-A PJ4A-3 (LOCK) 7-D. 5 Change PWB-A. 6 Change PU.U.
Description: Polygon Motor malfunction
• A LOW Motor Lock signal is not detected even after the lapse of a predetermined period of time after the Polygon Motor has been started. • The Motor Lock signal remains HIGH for a predetermined consecutive period of time while the Polygon Motor remains energized.
Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-A.
Description: Laser malfunction
• The SOS signal is not detected within a predetermined period of time after the output of a laser has been started. • The SOS signal is never detected in the image area.
Remedy: 1 Check the cable and connector for proper connection and correct as necessary. 2 Change PH Unit. 3 Change PWB-A.
Description: 2nd image transfer pressure /retraction failure
• The state of the Retraction Position Sensor/2nd Image Transfer is not changed from the unblocked to blocked state even after the lapse of a predetermined period of time during predrive. • The Retraction Position Sensor/2nd Image Transfer is in the unblocked state even after the lapse of a predetermined period of time during predrive. • The Retraction Position Sensor/2nd Image Transfer is not blocked (roller in the retracted position) within a predetermined period of time after the retraction sequence of the 2nd Transfer Roller has been started. • The Retraction Position Sensor/2nd Image Transfer is not unblocked (roller in the pressed position) within a predetermined period of time after the pressure sequence of the 2nd Transfer Roller has been started.
Remedy: 1 Check the M1 connector for proper connection and correct as necessary. 2 Check M1 for proper drive coupling and correct as necessary. 3 Check the SL4 connector for proper connection and correct as necessary. 4 Check the PWB-A connector for proper connection and correct as necessary. 5 PC5 sensor check. PWB-A PJ14A-3 (ON) 2-G 6 SL4 operation check. PWB-A PJ11A-2 (REM) 2-G 7 M1 operation check. PWB-A PJ8A-5 (REM) PWB-A PJ8A-8 (LOCK) 2-G-H 8 Change PWB-A.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.