Code: 21

Description: Faulty OHP sensor
• It is determined that the OHP sensor is faulty through a check made at the end of the predrive.
Remedy: 1 Check the PRCB connector for proper connection and correct as necessary. 2 PS2 sensor check. 2500W: PRCB PJ12PRCB-6 (ON) 2530 DL: PRCB PJ12PRCB-6 (ON) 2550/2550DN: PRCB PJ12PRCB-6 (ON) 2500W: C-10 2530 DL: C-9 2550/2550DN: C-9. 3 Change PRCB.

Code: 24

Description: Faulty fusing thermistor resistor
• The heater lamp remains ON for a predetermined consecutive period of time.
Remedy: 1 Check the PRCB connector for proper connection and correct as necessary. 2 Change fusing unit. 3 Change PRCB.

Code: 29

Description: Trouble related to security
Remedy:

Code: 2A

Description: Trouble related to security
Remedy:

Code: 2B

Description: Trouble related to security
Remedy:

Code: 2C

Description: Trouble related to security
Remedy: