Description: Abnormally high heating roller temperature
• The temperature detected by the thermistor /1 remains higher than the specified value for a given period of time or longer. • The heater lamp remains ON for a given period of time or longer.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fusing unit. 4 Change MFPB. 5 Change DCPU.
Code: 0521
Display: FUSER ERROR
Description: Abnormally high fusing pressure roller temperature
• The temperature detected by the thermistor /2 remains higher than the specified value for a given period of time or longer.
Remedy: 1 Check the fusing unit for correct installation (whether it is secured in position). 2 Check the fusing unit, DCPU, and MFPB for proper connection and correct as necessary. 3 Change fusing unit. 4 Change MFPB. 5 Change DCPU.