Các lỗi thường gặp

Code :
  • Code: F041
  • Description: Control PWB - scanner PWB communication error
    A communication error is detected.
  • Causes: Defective control PWB or scanner PWB.
  • Remedy: Defective control PWB or scanner PWB. Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB or scanner PWB.
  • Code: F050
  • Description: Control PWB engine checksum error
  • Causes: Some error may have occurred when downloading the firmware of the control PWB. Defective control PWB.
  • Remedy: Some error may have occurred when downloading the firmware of the control PWB. Download the firmware of the control PWB again.
    Defective control PWB. Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB.
  • Code: F186
  • Description: Control PWB video data control error
  • Causes: Defective control PWB.
  • Remedy: Defective control PWB. Turn the power switch off/on to restart the machine. If the error is not resolved, replace control PWB.