Mã lỗi Kyocera ECOSYS M6026cdn — Trang 2/11

Code: 0180

Description: Machine number mismatch
Machine number of main and engine does not match.
Causes: Data damage of EEPROM.
Remedy: Data damage of EEPROM. Contact the Service Administrative Division.

Code: 0600

Description: Expanded memory (DIMM) installing error
The expansion memory modules (DIMM) are not correctly mounted.
Causes: Improper installation expanded memory (DIMM).
Remedy: Improper installation expanded memory (DIMM). Check the installation of the expanded memory (DIMM).

Code: 0610

Description: Expanded memory (DIMM) error
The expansion memory modules (DIMM) mounted on the main PWB does not operate correctly.
Causes: Defective expanded memory (DIMM). Defective main PWB.
Remedy: Defective expanded memory (DIMM). Replace the expanded memory (DIMM) and check for correct operation.
Defective main PWB. Replace the main PWB and check for correct operation.

Code: 0640

Description: Hard disk error
The hard disk cannot be accessed.
Causes: Defective hard disk. Defective main PWB.
Remedy: Defective hard disk. Replace the hard disk and check for correct operation.
Defective main PWB. Replace the main PWB and check for correct operation.

Code: 0830

Description: FAX control PWB flash program area checksum error
A checksum error occurred with the program of the FAX control PWB.
Causes: Defective FAX software. Defective FAX control PWB.
Remedy: Defective FAX software. Install the fax software.
Defective FAX control PWB. Replace the FAX control PWB.

Code: 0840

Description: Faults of RTC
The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed.
Causes: The battery is disconnected from the main PWB. Defective main PWB.
Remedy: The battery is disconnected from the main PWB. Check visually and remedy if necessary
Defective main PWB. Replace the main PWB and check for correct operation.

Code: 0870

Description: FAX control PWB to main PWB high capacity data transfer error
High-capacity data transfer between the FAX control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times.
Causes: Improper installation FAX control PWB. Defective FAX control PWB or main PWB.
Remedy: Improper installation FAX control PWB. Reinstall the FAX control PWB.
Defective FAX control PWB or main PWB. Replace the FAX control PWB or main PWB and check for correct operation.

Code: 0920

Description: Fax file system error
The backup data is not retained for file system abnormality of flash memory of the FAX control PWB.
Causes: Defective FAX control PWB.
Remedy: Defective FAX control PWB. Replace the FAX control PWB and check for correct operation.