Description: Abnormality detecting in the system Management Department
Remedy: (1) U021 Controller backup initialization is carried out and an operation check is performed. (2) Exchange a Main board and perform an operation check. (3) Get USBLOG and contact service headquarters.
Code: F2BX, F2CX, F2DX
Description: Abnormality detecting in a network control part
Remedy: (1) Exchange a Main/Engine PWB and perform an operation check. (2) Get USBLOG and contact service headquarters.(Depending on an analysis result, it is packet capture acquisition)
Code: F2EX, F2FX, F30X
Description: Abnormality detecting in a network control part
Remedy: (1) Exchange a Main/Engine PWB and perform an operation check. (2) Get USBLOG and contact service headquarters.(Depending on an analysis result, it is packet capture acquisition)
Code: F31X, F32X
Description: Abnormality detecting in a network control part
Remedy: (1) Exchange a Main/Engine PWB and perform an operation check. (2) Get USBLOG and contact service headquarters.(Depending on an analysis result, it is packet capture acquisition)
Code: F35X
Description: Abnormality detecting in the printing controlling Management Department
Remedy: (1) Exchange a Main/Engine PWB and perform an operation check. (2) Get USBLOG and contact service headquarters.
Code: F38X
Description: Abnormality detecting in the authentication authorized Management Department
Remedy: (1) Exchange a Main/Engine PWB and perform an operation check. (2) Get USBLOG and contact service headquarters.
Code: F3AX, F3BX, F3CX
Description: Abnormality detecting in the Entity Management Department
Remedy: (1) Exchange a Main/Engine PWB and perform an operation check. (2) Get USBLOG and contact service headquarters
Code: F3DX, F3EX, F3FX
Description: Abnormality detecting in the Entity Management Department