Các lỗi thường gặp

Code :
  • Code: 0800
  • Description: Image processing error JAM010x and JAM21 are detected twice.
  • Remedy: Defective main PWB. Replace the main PWB and check for correct operations page 1-5-38).
  • Code: 0840
  • Description: Faults of RTC The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed.
  • Remedy: The battery is disconnected from the main PWB. Check visually and remedy if necessary
    Defective main PWB. Replace the main PWB and check for correct operation.
  • Code: 1010
  • Description: Lift motor error After cassette 1 is inserted, lift sensor does not turn on within 10 s. This error is detected five times successively.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Lift motor and engine PWB (YC13)
    Defective drive transmission system of the lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective lift motor. Replace the lift motor.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 1020
  • Description: PF lift motor 1 error (paper feeder) After cassette 2 is inserted, PF lift sensor 1 does not turn on. This error is detected five times successively.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 1 and PF main PWB (YC7)
    Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF lift motor. Replace the PF lift motor 1.
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 1030
  • Description: PF lift motor 2 error (paper feeder) After cassette 3 is inserted, PF lift sensor 2 does not turn on. This error is detected five times successively.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 2 and PF main PWB (YC7)
    Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF lift motor. Replace the PF lift motor 2.
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 1040
  • Description: PF lift motor 3 error (paper feeder) After cassette 4 is inserted, PF lift sensor 3 does not turn on. This error is detected five times successively.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 3 and PF main PWB (YC7)
    Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF lift motor. Replace the PF lift motor 3.
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 1050
  • Description: PF lift motor 4 error (paper feeder) After cassette 5 is inserted, PF lift sensor 4 does not turn on. This error is detected five times successively.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 4 and PF main PWB (YC7)
    Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF lift motor. Replace the PF lift motor 4.
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 1800
  • Description: Paper feeder 1 communication error A communication error is detected 10 times in succession.
  • Remedy: Improper installation paper feeder. Follow installation instruction carefully again.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF main PWB (YC3) and engine PWB (YC22)
    Defective engine PWB. Replace the engine PWB and check for correct operation.
    Defective PF main PWB. Replace the PF main PWB.
 < 1 2 3 4 5 >  Last ›
popup

Số lượng:

Tổng tiền:

Danh mục