Description: Abnormality detecting in a device control section
Remedy: Initialize HDD and perform an operation check. (FULL of U024) * Carry out U021 Main backup initialization and perform an operation check. Exchange a Main board and perform an operation check. Exchange HDD and perform an operation check. * Get USBLOG and contact service headquarters. * Execution of U024 will vanish user data and the software installed. Reinstallation is required.
Code: F68X
Description: Abnormality detecting in a storage device control section
Remedy: Initialize HDD and perform an operation check. (FULL of U024) * Carry out U021 Main backup initialization and perform an operation check. Exchange a Main board and perform an operation check. Exchange HDD and perform an operation check. * Get USBLOG and contact service headquarters. * F684 is the overwrite error at the time of an HDD security kit. * Execution of U024 will vanish user data and the software installed. Reinstallation is required.
Code: F69X, F6AX, F6BX, F6CX
Description: Abnormality detecting in a HyPAS-E part
Remedy: Initialize HDD and perform an operation check. (FULL of U024) * Carry out U021 Main backup initialization and perform an operation check. Exchange a Main board and perform an operation check. Exchange HDD and perform an operation check. * Get USBLOG and contact service headquarters. * Execution of U024 will vanish user data and the software installed. Reinstallation is required.
Code: F6DX, F6EX, F6FX, F71X
Description: Abnormality detecting in the external server Management Department
Remedy: Check an external server and perform an operation check. Check connection with an external server and perform an operation check. network setup is checked and an operation check is performed. Exchange a Bridge board and perform an operation check. Exchange a Main board and perform an operation check. Get USBLOG and contact service headquarters. * FieryOption relation
Code: F72X, F73X, F74X, F75X
Description: Abnormality detecting in the external server Management Department
Remedy: Check an external server and perform an operation check. Check connection with an external server and perform an operation check. network setup is checked and an operation check is performed. Exchange a Bridge board and perform an operation check. Exchange a Main board and perform an operation check. Get USBLOG and contact service headquarters. * FieryOption relation