Các lỗi thường gặp

Code :
  • Code: F63X
  • Description: Abnormality detecting in a device control section
  • Remedy: Initialize HDD and perform an operation check. (FULL of U024) * Carry out U021 Main backup initialization and perform an operation check. Exchange a Main board and perform an operation check. Exchange HDD and perform an operation check. * Get USBLOG and contact service headquarters. * Execution of U024 will vanish user data and the software installed. Reinstallation is required.
  • Code: F68X
  • Description: Abnormality detecting in a storage device control section
  • Remedy: Initialize HDD and perform an operation check. (FULL of U024) * Carry out U021 Main backup initialization and perform an operation check. Exchange a Main board and perform an operation check. Exchange HDD and perform an operation check. * Get USBLOG and contact service headquarters. * F684 is the overwrite error at the time of an HDD security kit. * Execution of U024 will vanish user data and the software installed. Reinstallation is required.
  • Code: F69X, F6AX, F6BX, F6CX
  • Description: Abnormality detecting in a HyPAS-E part
  • Remedy: Initialize HDD and perform an operation check. (FULL of U024) * Carry out U021 Main backup initialization and perform an operation check. Exchange a Main board and perform an operation check. Exchange HDD and perform an operation check. * Get USBLOG and contact service headquarters. * Execution of U024 will vanish user data and the software installed. Reinstallation is required.
  • Code: F6DX, F6EX, F6FX, F71X
  • Description: Abnormality detecting in the external server Management Department
  • Remedy: Check an external server and perform an operation check. Check connection with an external server and perform an operation check. network setup is checked and an operation check is performed. Exchange a Bridge board and perform an operation check. Exchange a Main board and perform an operation check. Get USBLOG and contact service headquarters. * FieryOption relation
  • Code: F72X, F73X, F74X, F75X
  • Description: Abnormality detecting in the external server Management Department
  • Remedy: Check an external server and perform an operation check. Check connection with an external server and perform an operation check. network setup is checked and an operation check is performed. Exchange a Bridge board and perform an operation check. Exchange a Main board and perform an operation check. Get USBLOG and contact service headquarters. * FieryOption relation