Mã lỗi Kyocera FS2000D

Code: 0150

Description: Engine PWB EEPROM error
Detecting engine PWB EEPROM communication error.
Causes: Improper installation engine PWB EEPROM. Defective engine PWB
Remedy: Improper installation engine PWB EEPROM. Check the engine PWB EEPROM installation, Remedy.
Defective engine PWB Replace the engine PWB.

Code: 0420

Description: Paper feeder communication error Communication error between engine PWB and optional paper feeder.
Causes: Improper installation paper feeder. Defective harness between connect-L PWB (YC2) and paper feeder interface connector, or improper connector insertion. Defective harness between connect-L PWB (YC6) and engine PWB (YC4), or improper connector insertion. Defective engine PWB. Defective paper feeder.
Remedy: Improper installation paper feeder. Follow installation instruction carefully again.
Defective harness between connect-L PWB (YC2) and paper feeder interface connector, or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
Defective harness between connect-L PWB (YC6) and engine PWB (YC4), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
Defective engine PWB. Replace the engine PWB.
Defective paper feeder. Replace the paper feeder.

Code: 1010

Description: Lift motor lock error
*35/37 and 45/47 ppm printers (EUR/ USA model) only A motor over-current signal is detected continuously for 5 seconds since the lift motor is activated.
Causes: Defective bottom plate elevation mechanism in the paper cassette. Defective lift motor drive transmission system. Defective lift motor. Defective engine PWB.
Remedy: Defective bottom plate elevation mechanism in the paper cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
Defective lift motor drive transmission system. Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
Defective lift motor. Replace the lift motor.
Defective engine PWB. Replace the engine PWB.

Code: 1140

Description: Lift motor ascent error
*35/37 and 45/47 ppm printers (EUR/ USA model) only Optional bulk paper feeder’s tray top position sensor does not turn on. Lift motor lock error occurred 3 times.
Causes: Defective bulk paper feeder’s tray top position sensor. Defective harness between bulk paper feeder’s tray top position sensor and main PWB (YC6), or improper connector insertion. Defective bulk paper feeder’s main PWB.
Remedy: Defective bulk paper feeder’s tray top position sensor. Replace the bulk paper feeder’s tray top position sensor.
Defective harness between bulk paper feeder’s tray top position sensor and main PWB (YC6), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
Defective bulk paper feeder’s main PWB. Replace the bulk paper feeder’s main PWB.

Code: 1150

Description: Lift motor descent error
*35/37 and 45/47 ppm printers (EUR/ USA model) only Optional bulk paper feeder’s tray bottom position sensor does not turn on. Lift motor lock error occurred 3 times.
Causes: Defective bulk paper feeder’s tray bottom position sensor. Defective harness between bulk paper feeder’s tray bottom position sensor and main PWB (YC8), or improper connector insertion. Defective bulk paper feeder’s main PWB.
Remedy: Defective bulk paper feeder’s tray bottom position sensor. Replace the bulk paper feeder’s tray bottom position sensor.
Defective harness between bulk paper feeder’s tray bottom position sensor and main PWB (YC8), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
Defective bulk paper feeder’s main PWB. Replace the bulk paper feeder’s main PWB.

Code: 2000

Description: Main motor error
MMOTRDYN signal does not go low within 2 s after MMOTONN signal goes low.feeder.D
Causes: Defective harness between main motor and engine PWB (YC10), or improper connector insertion. Defective main motor drive transmission system. Defective main motor. Defective engine PWB.
Remedy: Defective harness between main motor and engine PWB (YC10), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
Defective main motor drive transmission system. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
Defective main motor. Replace the main motor.
Defective engine PWB. Replace the engine PWB.

Code: 2200

Description: Drum motor error
DMOTRDYN signal does not go low within 2 s after DMOTONN signal goes low.
Causes: Defective harness between drum motor and engine PWB (YC11), or improper connector insertion. Defective drum motor drive transmission system. Defective drum motor. Defective engine PWB.
Remedy: Defective harness between drum motor and engine PWB (YC11), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
Defective drum motor drive transmission system. Check if the gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any.
Defective drum motor. Replace the drum motor.
Defective engine PWB. Replace the engine PWB.

Code: 4000

Description: Polygon motor (laser scanner unit) error
POLRDYN signal does not go low within 2 s after POLONN signal goes low.
Causes: Defective harness between polygon motor and main PWB (YC10), or improper connector insertion. Defective harness between main PWB (YC11) and engine PWB (YC12), or improper connector insertion. Defective laser scanner unit. Defective engine PWB. Defective main PWB.
Remedy: Defective harness between polygon motor and main PWB (YC10), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
Defective harness between main PWB (YC11) and engine PWB (YC12), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness.
Defective laser scanner unit. Replace the laser scanner unit.
Defective engine PWB. Replace the engine PWB.
Defective main PWB. Replace the main PWB.