Các lỗi thường gặp

Code :
  • Code: 0800
  • Description: Image processing error
    JAM010x is detected twice.
  • Causes: Defective main PWB.B.
  • Remedy: Replace the main PWB and check for correct operations page 1-5-22).
  • Code: 0840
  • Description: Faults of RTC
    The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed.
  • Causes: The battery is disconnected from the main PWB. Defective main PWB.
  • Remedy: The battery is disconnected from the main PWB. Check visually and remedy if necessary
    Defective main PWB. Replace the main PWB and check for correct operation.
  • Code: 1010
  • Description: Lift motor error
    (60/50/45 ppm model only) After cassette 1 is inserted, lift sensor does not turn on within 10 s. This error is detected four times successively.
  • Causes: Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the lift motor. Defective lift motor. Defective engine PWB.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Lift motor and engine PWB (YC13)
    Defective drive transmission system of the lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective lift motor. Replace the lift motor.
    Defective engine PWB. Replace the engine PWB and check for correct operation.
  • Code: 1020
  • Description: PF lift motor 1 error (paper feeder)
    After cassette 2 is inserted, PF lift sensor 1 does not turn on. This error is detected four times successively.
  • Causes: Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 1 and PF main PWB (YC7)
    Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF lift motor. Replace the PF lift motor 1.
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 1030
  • Description: PF lift motor 2 error (paper feeder)
    After cassette 3 is inserted, PF lift sensor 2 does not turn on. This error is detected four times successively.
  • Causes: Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 2 and PF main PWB (YC7)
    Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF lift motor. Replace the PF lift motor 2.
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 1040
  • Description: PF lift motor 3 error (paper feeder)
    After cassette 4 is inserted, PF lift sensor 3 does not turn on. This error is detected four times successively.
  • Causes: Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 3 and PF main PWB (YC7)
    Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF lift motor. Replace the PF lift motor 3.
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 1050
  • Description: PF lift motor 4 error (paper feeder)
    After cassette 5 is inserted, PF lift sensor 4 does not turn on. This error is detected four times successively
  • Causes: Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB.
  • Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found.
    Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor 4 and PF main PWB (YC7)
    Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective PF lift motor. Replace the PF lift motor 4.
    Defective PF main PWB. Replace the PF main PWB.
  • Code: 1140
  • Description: BPF lift motor upward error (Bulk paper feeder)
    BPF lift maximum sensor does not turn on. The lock signal of the motor is detected continuously three times.
  • Causes: Defective connector cable or poor contact in the connector. Defective drive transmission system of the motor. Defective BPF lift motor. Defective BPF main PWB.
  • Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. BPF lift motor and BPF main PWB
    Defective drive transmission system of the motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any.
    Defective BPF lift motor. Replace the BPF lift motor.
    Defective BPF main PWB. Replace the BPF main PWB.