Code: 9500

Description: BRU communication error
Causes: IPU PWB error
Remedy: Contact the Service Administrative Division.

Code: 9510

Description: BRU PWB error
Causes: IPU PWB error
Remedy: Contact the Service Administrative Division.

Code: 9520

Description: BRU PWB data error
Causes: IPU PWB error
Remedy: Contact the Service Administrative Division.

Code: 9530

Description: Machine No.backup error C
Causes: IPU PWB error
Remedy: Contact the Service Administrative Division.

Code: 9540

Description: Machine No.backup error D
Causes: IPU PWB error
Remedy: Contact the Service Administrative Division.

Code: 9550

Description: Machine No.backup error E
Causes: IPU PWB error
Remedy: Contact the Service Administrative Division.

Code: F000

Description: Main PWB - operation panel PWB communication error
Causes: Defective main PWB.
Defective operation panel PWB.
Remedy: Defective main PWB. Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.
Defective operation panel PWB. Replace the operation panel PWB and check for correct operation.

Code: F010, F011, F012, F013

Description: Main PWB checksum error
Causes: Defective main PWB.
Remedy: Turn the main power switch off/on to restart the machine. If the error is not resolved, replace main PWB.