  • Code: 0160
  • Description: Backup memory data error (engine PWB)
  • Causes: Defective flash memory.
    Defective engine PWB.
  • Remedy: Replace the engine PWB and check for correct operation.
  • Code: 0170
  • Description: Billing counting error
    A checksum error is detected in the main and engine backup memories for the billing counters.
  • Causes: Data damage of EEPROM.
    Defective PWB.
  • Remedy: Data damage of EEPROM. Contact the Service Administrative Division.
    Defective PWB. Replace the main PWB or the engine PWB and check for correct operation.
  • Code: 0180
  • Description: Machine number mismatch
    Machine number of main and engine does not match.
  • Causes: Data damage of EEPROM.
  • Remedy: Data damage of EEPROM. Contact the Service Administrative Division.
  • Code: 0320
  • Description: I/O CPU communication error
    A communication error is detected 10 times in succession.
  • Causes: Defective PWB.
  • Remedy: Defective PWB. Replace the main PWB or the engine PWB and check for correct operation.(see page 1- 5-33,1-5-34)
  • Code: 0800
  • Description: Image processing error
    JAM05 is detected twice.
  • Causes: Defective main PWB.
  • Remedy: Replace the main PWB and check for correct operation(see page 1-5-33).
  • Code: 0830
  • Description: FAX control PWB flash program area checksum error
    A checksum error occurred with the program of the FAX control PWB.
  • Causes: Defective FAX software.
    Defective FAX control PWB.
  • Remedy: Defective FAX software. Install the fax software.
    Defective FAX control PWB. Replace the FAX control PWB.
  • Code: 0840
  • Description: Faults of RTC
    The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed.
  • Causes: The battery is disconnected from the main PWB.
    Defective main PWB.
  • Remedy: The battery is disconnected from the main PWB. Check visually and remedy if necessary
    Defective main PWB. Replace the main PWB and check for correct operation.
  • Code: 0870
  • Description: FAX control PWB to main PWB high capacity data transfer error
    High-capacity data transfer between the FAX control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times.
  • Causes: Improper installation FAX control PWB.
    Defective FAX control PWB or main PWB.
  • Remedy: Improper installation FAX control PWB. Reinstall the FAX control PWB.
    Defective FAX control PWB or main PWB. Replace the FAX control PWB or main PWB and check for correct operation.