Remedy: Replace the engine PWB and check for correct operation.
Code: 0170
Description: Billing counting error A checksum error is detected in the main and engine backup memories for the billing counters.
Causes: Data damage of EEPROM. Defective PWB.
Remedy: Data damage of EEPROM. Contact the Service Administrative Division. Defective PWB. Replace the main PWB or the engine PWB and check for correct operation.
Code: 0180
Description: Machine number mismatch Machine number of main and engine does not match.
Causes: Data damage of EEPROM.
Remedy: Data damage of EEPROM. Contact the Service Administrative Division.
Code: 0320
Description: I/O CPU communication error A communication error is detected 10 times in succession.
Causes: Defective PWB.
Remedy: Defective PWB. Replace the main PWB or the engine PWB and check for correct operation.(see page 1- 5-33,1-5-34)
Code: 0800
Description: Image processing error JAM05 is detected twice.
Causes: Defective main PWB.
Remedy: Replace the main PWB and check for correct operation(see page 1-5-33).
Code: 0830
Description: FAX control PWB flash program area checksum error A checksum error occurred with the program of the FAX control PWB.
Causes: Defective FAX software. Defective FAX control PWB.
Remedy: Defective FAX software. Install the fax software. Defective FAX control PWB. Replace the FAX control PWB.
Code: 0840
Description: Faults of RTC The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed.
Causes: The battery is disconnected from the main PWB. Defective main PWB.
Remedy: The battery is disconnected from the main PWB. Check visually and remedy if necessary Defective main PWB. Replace the main PWB and check for correct operation.
Code: 0870
Description: FAX control PWB to main PWB high capacity data transfer error High-capacity data transfer between the FAX control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times.
Causes: Improper installation FAX control PWB. Defective FAX control PWB or main PWB.
Remedy: Improper installation FAX control PWB. Reinstall the FAX control PWB. Defective FAX control PWB or main PWB. Replace the FAX control PWB or main PWB and check for correct operation.