Các lỗi thường gặp

Code :
  • Code: 0180
  • Description: Machine number mismatch
    Machine number of main and engine does not match.
  • Causes: Data damage of EEPROM.
  • Remedy: Data damage of EEPROM. Contact the Service Administrative Division.
  • Code: 0600
  • Description: Expanded memory (DIMM) installing error
    The expansion memory modules (DIMM) are not correctly mounted.
  • Causes: Improper installation expanded memory (DIMM).
  • Remedy: Improper installation expanded memory (DIMM). Check the installation of the expanded memory (DIMM).
  • Code: 0610
  • Description: Expanded memory (DIMM) error
    The expansion memory modules (DIMM) mounted on the main PWB does not operate correctly.
  • Causes: Defective expanded memory (DIMM). Defective main PWB.
  • Remedy: Defective expanded memory (DIMM). Replace the expanded memory (DIMM) and check for correct operation.
    Defective main PWB. Replace the main PWB and check for correct operation.
  • Code: 0640
  • Description: Hard disk error
    The hard disk cannot be accessed.
  • Causes: Defective hard disk. Defective main PWB.
  • Remedy: Defective hard disk. Replace the hard disk and check for correct operation.
    Defective main PWB. Replace the main PWB and check for correct operation.
  • Code: 0830
  • Description: FAX control PWB flash program area checksum error
    A checksum error occurred with the program of the FAX control PWB.
  • Causes: Defective FAX software. Defective FAX control PWB.
  • Remedy: Defective FAX software. Install the fax software.
    Defective FAX control PWB. Replace the FAX control PWB.
  • Code: 0840
  • Description: Faults of RTC
    The time is judged to go back based on the comparison of the RTC time and the current time or five years or more have passed.
  • Causes: The battery is disconnected from the main PWB. Defective main PWB.
  • Remedy: The battery is disconnected from the main PWB. Check visually and remedy if necessary
    Defective main PWB. Replace the main PWB and check for correct operation.
  • Code: 0870
  • Description: FAX control PWB to main PWB high capacity data transfer error
    High-capacity data transfer between the FAX control PWB and the main PWB of the machine was not normally performed even if the data transfer was retried the specified times.
  • Causes: Improper installation FAX control PWB. Defective FAX control PWB or main PWB.
  • Remedy: Improper installation FAX control PWB. Reinstall the FAX control PWB.
    Defective FAX control PWB or main PWB. Replace the FAX control PWB or main PWB and check for correct operation.
  • Code: 0920
  • Description: Fax file system error
    The backup data is not retained for file system abnormality of flash memory of the FAX control PWB.
  • Causes: Defective FAX control PWB.
  • Remedy: Defective FAX control PWB. Replace the FAX control PWB and check for correct operation.