Description: LSU cleaning motor error A LSU cleaning motor over-current signal is detected for 5 seconds in total while the LSU cleaning motor is ON.
Causes: Defective harness between LSU cleaning motor and engine PWB (YC37), or improper connector insertion. Defective drive transmission system of the LSU cleaning motor. Defective LSU cleaning motor. Defective engine PWB.
Remedy: Defective harness between LSU cleaning motor and engine PWB (YC37), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Defective drive transmission system of the LSU cleaning motor. Check if the rollers and gears rotate smoothly. If not, grease the bushings and gears. Check for broken gears and replace if any. Defective LSU cleaning motor. Replace the LSU cleaning motor. Defective engine PWB. Replace the engine PWB.
Code: 4700
Description: VIDEO ASIC device error (Main PWB) Data read from EEPROM is judged abnormal.
Causes: Defective main PWB.
Remedy: Defective main PWB. Replace the main PWB.
Code: 5301
Description: Broken eraser lamp K wire A disconnection detection signal for eraser lamp K is detected for one second while eraser lamp K is ON.is ON.
Causes: Defective harness between drum unit K and drum relay PWB (YC2/YC3), or improper connector insertion. Defective harness between drum relay PWB (YC1) and engine PWB (YC34), or improper connector insertion. Defective eraser lamp K. Defective engine PWB.
Remedy: Defective harness between drum unit K and drum relay PWB (YC2/YC3), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Defective harness between drum relay PWB (YC1) and engine PWB (YC34), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Defective eraser lamp K. Replace the drum unit K.. Defective engine PWB. Replace the engine PWB.
Code: 5302
Description: Broken eraser lamp C wire A disconnection detection signal for eraser lamp C is detected for one second while eraser lamp C is ON.is ON.
Causes: Defective harness between drum unit C and drum relay PWB (YC8/YC9), or improper connector insertion. Defective harness between drum relay PWB (YC1) and engine PWB (YC34), or improper connector insertion. Defective eraser lamp C. Defective engine PWB.
Remedy: Defective harness between drum unit C and drum relay PWB (YC8/YC9), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Defective harness between drum relay PWB (YC1) and engine PWB (YC34), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Defective eraser lamp C. Replace the drum unit C. Defective engine PWB. Replace the engine PWB.
Code: 5303
Description: Broken eraser lamp M wire A disconnection detection signal for eraser lamp M is detected for one second while eraser lamp M is ON.is ON.
Causes: Defective harness between drum unit M and drum relay PWB (YC11/ YC12), or improper connector insertion. Defective harness between drum relay PWB (YC1) and engine PWB (YC34), or improper connector insertion. Defective eraser lamp M. Defective engine PWB.
Remedy: Defective harness between drum unit M and drum relay PWB (YC11/ YC12), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Defective harness between drum relay PWB (YC1) and engine PWB (YC34), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Defective eraser lamp M. Replace the drum unit M. Defective engine PWB. Replace the engine PWB.
Code: 5304
Description: Broken eraser lamp Y wire A disconnection detection signal for eraser lamp Y is detected for one second while eraser lamp Y is ON.is ON.
Causes: Defective harness between drum unit Y and drum relay PWB (YC5/YC6), or improper connector insertion. Defective harness between drum relay PWB (YC1) and engine PWB (YC34), or improper connector insertion. Defective eraser lamp Y. Defective engine PWB.
Remedy: Defective harness between drum unit Y and drum relay PWB (YC5/YC6), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Defective harness between drum relay PWB (YC1) and engine PWB (YC34), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Defective eraser lamp Y. Replace the drum unit Y. Defective engine PWB. Replace the engine PWB.
Code: 6000
Description: Broken fuser heater lamp wire The detected fuser thermistor temperature does not rise 1°C/1.8°F after the fuser heater lamp has been turned on continuously for 5 seconds in warming up. The fuser temperature does not reach 100°C/212°F after the fuser heater lamp has been turned on continuously for 30 seconds in warming up. The temperature does not rise 1°C/1.8°F after the fuser heater lamp has been turned on continuously 5 s.
Causes: Defective harness between fuser thermistor and paper exit PWB (YC4), or improper connector insertion. Defective harness between paper exit PWB (YC1) and engine PWB (YC20), or improper connector insertion. Fuser thermistor installed incorrectly. Fuser thermal cutout triggered. Fuser heater lamp installed incorrectly. Broken fuser heater lamp wire. Defective engine PWB.
Remedy: Defective harness between fuser thermistor and paper exit PWB (YC4), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Defective harness between paper exit PWB (YC1) and engine PWB (YC20), or improper connector insertion. Reinsert the connector. Also check for continuity within the connector harness. If none, remedy or replace the harness. Fuser thermistor installed incorrectly. Replace the fuser unit. Fuser thermal cutout triggered. Replace the fuser unit. Fuser heater lamp installed incorrectly. Replace the fuser unit. Broken fuser heater lamp wire. Replace the fuser unit. Defective engine PWB. Replace the engine PWB.
Code: 6020
Description: Abnormally high fuser thermistor temperature The fuser thermistor detects a temperature higher than 220°C/428°F for 10 seconds. The fuser thermistor detects a temperature higher than 240°C/464°F for 1 second.