Description: Backup memory data problem • Data in the specified area of the backup memory does not match the specified values.
Causes: Problem with the backup memory data. Defective backup RAM.
Remedy: Turn safety switch 1 off and back on and run maintenance item U020 to set the contents of the backup memory data again. If the C011 is displayed after re-setting the backup memory contents, replace the backup RAM.
Description: Operation unit main PCB communication problem • There is no reply after 20 retries at communication.
Causes: Poor contact of the connector terminals. Defective main PCB or operation unit main PCB.
Remedy: Check the connection of connectors CN6 on the main PCB and CN6 on the operation unit main PCB, and the continuity across the connector terminals. Repair or replace if necessary. Replace the main PCB or operation unit main PCB and check for correct operation.
Description: Printer board communication problem*2 •There is no reply after 20 retries at communication.
Causes: Poor contact of the connector terminals. Defective main PCB or printer board.
Remedy: Check the connection of connector CN4 on the main PCB and the connector on the printer board. Repair or replace if necessary. Replace the main PCB or printer board and check for correct operation.