Description: Polygon motor synchronization problem • The polygon motor does not reach the stable speed within 9 s of the START signal turning on.
Causes: Poor contact in the polygon motor connector terminals. Defective polygon motor. Defective power source PCB. Defective engine PCB.
Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the LSU. Check if 24 V DC is supplied to CN1-4 on the main PCB. If not, replace the power source PCB. Check if 24 V DC is output from CN14-14 on the engine PCB. If not, replace the main PCB.
Description: Polygon motor steady-state problem • The polygon motor rotation is not stable for 600 ms after the polygon motor rotation has been stabilized.
Causes: Poor contact in the polygon motor connector terminals. Defective polygon motor. Defective power source PCB. Defective engine PCB.
Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, remedy or replace the cable. Replace the LSU. Check if 24 V DC is supplied to CN1-4 on the main PCB. If not, replace the power source PCB. Check if 24 V DC is output from CN14-14 on the engine PCB. If not, replace the main PCB.
Description: Drum surface potential sensor problem 1 Drum surface potential sensor output voltage is 0.5 V or less when MC REM signal is turn on. (except during stepping control)
Causes: Poor contact in the drum surface potential sensor connector terminals. Defective drum surface potential sensor. Defective engine PCB. Defective high voltage transformer PCB.
Remedy: Reinsert the connector. Also check for continuity within the connector cable. If none, repair or replace the cable. Replace the drum surface potential sensor. Replace the engine PCB and check for correct operation. Replace the high voltage transformer PCB and check for correct operation.
Description: Drum surface potential sensor problem 2 Drum surface potential sensor output voltage is 4.5 V or less when MC REM signal is turn on. (except during stepping control)
Causes: Defective drum surface potential sensor.
Remedy: Replace the drum surface potential sensor.
Description: Drum surface potential problem 1 • Maximizing the grid output cannot set the potential.
Causes: Deteriorated main charger. Grid or main charger shield is dirty. Defective high voltage transformer PCB. Defective engine PCB.
Remedy: Check the main charger wire and replace it if necessary. Clean the grid or main charger shield if necessary. Replace the high voltage transformer PCB and check for correct operation. Replace the engine PCB and check for correct operation.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.