Description: Developing unit M type mismatch problem Absence of the developing unit M is detected.
Causes: Developing unit connector inserted incorrectly. Different type of the developing unit is installed.
Remedy: Developing unit connector inserted incorrectly. Reinsert the developing unit connector if necessary. Different type of the developing unit is installed. Install the correct developing unit.
Code: C7404
Description: Developing unit Y type mismatch problem Absence of the developing unit Y is detected.
Causes: Developing unit connector inserted incorrectly. Different type of the developing unit is installed.
Remedy: Developing unit connector inserted incorrectly. Reinsert the developing unit connector if necessary. Different type of the developing unit is installed. Install the correct developing unit.
Code: C7411
Description: Drum unit BK type mismatch problem Absence of the drum unit BK is detected.
Causes: Drum unit connector inserted incorrectly. Different type of the drum unit is installed.
Remedy: Drum unit connector inserted incorrectly. Reinsert the drum unit connector if necessary. Different type of the drum unit is installed. Install the correct drum unit.
Code: C7412
Description: Drum unit C type mismatch problem Absence of the drum unit C is detected.
Causes: Drum unit connector inserted incorrectly. Different type of the drum unit is installed.
Remedy: Drum unit connector inserted incorrectly. Reinsert the drum unit connector if necessary. Different type of the drum unit is installed. Install the correct drum unit.
Code: C7413
Description: Drum unit M type mismatch problem Absence of the drum unit M is detected.
Causes: Drum unit connector inserted incorrectly. Different type of the drum unit is installed.
Remedy: Drum unit connector inserted incorrectly. Reinsert the drum unit connector if necessary. Different type of the drum unit is installed. Install the correct drum unit.
Code: C7414
Description: Drum unit Y type mismatch problem Absence of the drum unit Y is detected.
Causes: Drum unit connector inserted incorrectly. Different type of the drum unit is installed.
Remedy: Drum unit connector inserted incorrectly. Reinsert the drum unit connector if necessary. Different type of the drum unit is installed. Install the correct drum unit.
Code: C7420
Description: Transfer belt unit type mismatch problem Absence of the transfer belt unit is detected.
Causes: Transfer belt unit connector inserted incorrectly. Different type of the transfer belt unit is installed.
Remedy: Transfer belt unit connector inserted incorrectly. Reinsert the transfer belt unit connector if necessary. Different type of the transfer belt unit is installed. Install the correct transfer belt unit.
Code: C7800
Description: Broken external thermistor wire An abnormal value is detected in the input data to the outer temperature sensor.
Causes: Poor contact in the connector terminals. Defective engine PWB.
Remedy: Poor contact in the connector terminals. Check the connection of connector YC13 on the engine PWB and the continuity across the connector terminals. Repair or replace if necessary. Defective engine PWB. Replace the engine PWB and check for correct operation.