Description: Density Sensor Error Density Sensor cannot be calibrated correctly before Density Measure.
Remedy: Wires 1 Is the wire between Toner Density Sensor and PW11720 PCB connected properly? No Connect it properly. Density Sensor (PH8) 2 Can you fix the problem if you replace Density Sensor? No Replace PW11720 with a new one.
Code: E-0081
Description: Density Sensor Error Density Sensor cannot be calibrated correctly before Density Measure.
Remedy: Wires 1 Is the wire between Toner Density Sensor and PW11720 PCB connected properly? No Connect it properly. Density Sensor (PH8) 2 Can you fix the problem if you replace Density Sensor? No Replace PW11720 with a new one.
Code: E-0090
Description: Eraser Lamp Error 1. The connector J-227 / J-228 is not connected. 2. Eraser Lamp (PW6631) is broken.