Description: Lift motor error When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively.
Causes: Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the lift motor. Defective lift motor. Defective engine PWB.
Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. Lift motor and engine PWB (YC27) Defective drive transmission system of the lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any. Defective lift motor. Replace the lift motor Defective engine PWB. Replace the engine PWB and check for correct operation.
Description: PF lift motor error (paper feeder 1) When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively.
Causes: Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB.
Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor and PF main PWB (YC7) Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any. Defective PF lift motor. Replace the PF lift motor Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
Description: PF lift motor error (paper feeder 2) When the lift motor is driven, the motor over-current detection signal is detected continuously for 50 times (5 s) at 100 ms intervals. After the lift motor is driven, the ON status of lift sensor cannot be detected for 8 s. The cassette installed confirmation message is displayed on the operation panel, and even if the cassette is opened and closed, the cassette installed confirmation message is displayed 5 times successively.
Causes: Defective bottom plate elevation mechanism in the cassette. Defective connector cable or poor contact in the connector. Defective drive transmission system of the PF lift motor. Defective PF lift motor. Defective PF main PWB.
Remedy: Defective bottom plate elevation mechanism in the cassette. Check to see if the bottom plate can move smoothly and repair it if any problem is found. Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF lift motor and PF main PWB (YC7) Defective drive transmission system of the PF lift motor. Check if the gears rotate smoothly. If not, grease the bushes and gears. Check for broken gears and replace if any. Defective PF lift motor. Replace the PF lift motor Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
Description: PF heater 1 high temperature error (paper feeder 1) A temperature higher than 75C/167F is detected.
Causes: Defective connector cable or poor contact in the connector. Shorted PF thermistor 1. Defective PF fan motor 1. Defective PF main PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF fan motor 1 and PF main PWB (YC111) Shorted PF thermistor 1. Replace the top heater unit (Refer to the service manual for the paper feeder). Defective PF fan motor 1. Replace the top heater unit (Refer to the service manual for the paper feeder). Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
Description: PF heater 2 high temperature error (paper feeder 1) A temperature higher than 75C/167F is detected.
Causes: Defective connector cable or poor contact in the connector. Shorted PF thermistor 2. Defective PF fan motor 2. Defective PF main PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF fan motor 2 and PF main PWB (YC111) Shorted PF thermistor 2. Replace the side heater unit (Refer to the service manual for the paper feeder). Defective PF fan motor 2. Replace the side heater unit (Refer to the service manual for the paper feeder). Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
Description: PF heater 1 high temperature error (paper feeder 2) A temperature higher than 75C/167F is detected.
Causes: Defective connector cable or poor contact in the connector. Shorted PF thermistor 1. Defective PF fan motor 1. Defective PF main PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF fan motor 1 and PF main PWB (YC111) Shorted PF thermistor 1. Replace the top heater unit (Refer to the service manual for the paper feeder). Defective PF fan motor 1. Replace the top heater unit (Refer to the service manual for the paper feeder). Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
Description: PF heater 2 high temperature error (paper feeder 2) A temperature higher than 75C/167F is detected.
Causes: Defective connector cable or poor contact in the connector. Shorted PF thermistor 2. Defective PF fan motor 2. Defective PF main PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF fan motor 2 and PF main PWB (YC111) Shorted PF thermistor 2. Replace the side heater unit (Refer to the service manual for the paper feeder). Defective PF fan motor 2. Replace the side heater unit (Refer to the service manual for the paper feeder). Defective PF main PWB. Replace the PF main PWB (Refer to the service manual for the paper feeder).
Description: PF heater 1 low temperature error (paper feeder 1) An external temperature higher than + 5C/+ 9F is not detected when one minute elapses after PF heater 1 is turned on.
Causes: Defective connector cable or poor contact in the connector. PF thermistor 1 installed incorrectly. Defective PF thermistor 1. Broken PF heater 1. Defective PF heater PWB or PF main PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. PF heater 1 and PF heater PWB (YC1) PF heater PWB (YC3) and PF main PWB (YC113) PF thermistor 1 and PF main PWB (YC114) PF thermistor 1 installed incorrectly. Check the installation of the PF thermistor 1. Defective PF thermistor 1. Replace the top heater unit (Refer to the service manual for the paper feeder). Broken PF heater 1. Replace the top heater unit (Refer to the service manual for the paper feeder). Defective PF heater PWB or PF main PWB. Replace the PF heater PWB or PF main PWB (Refer to the service manual for the paper feeder).
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.