Description: LED fault detection When the power supply is turned on, the peak value of LED is 80hex or less.
Causes: Defective connector cable or poor contact in the connector. Defective CIS Defective DPSHD PWB.
Remedy: Defective connector cable or poor contact in the connector. Reinsert the connector. Also check for continuity within the connector cable. If none, replace the cable. CIS and DPSHD PWB (YC1) DPSHD PWB (YC1) and DP main PWB (YC10) Defective CIS. Replace CIS and check for correct operation. Defective DPSHD PWB. Replace the DPSHD PWB and check for correct operation.
Remedy: Rejector installed incorrectly. Check the rejector is properly installed and, if not, perform the corrective action. Defective rejector. Replace the rejector.
Description: Sensor error in coin vender change (Yen 10) Change is empty despite change is enough.
Causes: Coin jam in the change tube Poor contact in the connector. Defective change empty sensor. Defective coin vender control PWB.
Remedy: Coin jam in the change tube Check visually and remedy. Poor contact in the connector. Check if the change empty sensor is intact. Defective change empty sensor. Replace the coin mec. Defective coin vender control PWB. Replace the coin mec.
Description: Sensor error in coin vender change (Yen 50) Change is empty despite change is enough.
Causes: Coin jam in the change tube Poor contact in the connector. Defective change empty sensor. Defective coin vender control PWB.
Remedy: Coin jam in the change tube Check visually and remedy. Poor contact in the connector. Check if the change empty sensor is intact. Defective change empty sensor. Replace the coin mec. Defective coin vender control PWB. Replace the coin mec.
Description: Sensor error in coin vender change (Yen 100) Change is empty despite change is enough.
Causes: Coin jam in the change tube Poor contact in the connector. Defective change empty sensor. Defective coin vender control PWB.
Remedy: Coin jam in the change tube Check visually and remedy. Poor contact in the connector. Check if the change empty sensor is intact. Defective change empty sensor. Replace the coin mec. Defective coin vender control PWB. Replace the coin mec.
Description: Sensor error in coin vender change (Yen 500) Change is empty despite change is enough.
Causes: Coin jam in the change tube Poor contact in the connector. Defective change empty sensor. Defective coin vender control PWB.
Remedy: Coin jam in the change tube Check visually and remedy. Poor contact in the connector. Check if the change empty sensor is intact. Defective change empty sensor. Replace the coin mec. Defective coin vender control PWB. Replace the coin mec.