Các lỗi thường gặp

Code :
  • Code: F26X, F2AX
  • Description: An error is detected at the System management section
  • Causes:
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division
  • Code: F33X
  • Description: An error is detected at the Scan management section
  • Causes:
  • Remedy: 1. Check the wire or connector between Scan/DP PWB (CCD PWB or DP relay PWB) and Main/engine PWB and correct it if necessary. (Reconnect the connector or replace the wire) Check the operation after that. 2. Execute U021 (Init memory) and check function. 3. Replace the operation panel PWB and check function. 4. Replace the main/engine PWB and check function. 5. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F34X
  • Description: An error is detected at the Panel management section
  • Causes:
  • Remedy: 1. Check the wire and the connection of the connectors between the operation panel PWB and the main/engine PWB, and check function. (For HyPAS model only) 2. Execute U021 (Init memory) and check function. 3. Replace the operation panel PWB and check function. (For HyPAS model only) 4. Replace the main/engine PWB and check function. 5. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F35X
  • Description: An error is detected at the Print control section
  • Causes:
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F37X
  • Description: An error is detected at the FAX management section
  • Causes:
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F38X
  • Description: An error is detected at the Authentication/permit management section
  • Causes:
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division
  • Code: F3AX ... F45X
  • Description: An error is detected at the Entity control section
  • Causes:
  • Remedy: 1. Execute U021 (Init memory) and check function. 2. Replace the main/engine PWB and check function. 3. Retrieve the USBLOG and contact the Service Administrative Division.
  • Code: F46X
  • Description: An error is detected at the Print image process section
  • Causes:
  • Remedy: 1. Replace the main/engine PWB and check function. 2. Retrieve the USBLOG and contact the Service Administrative Division. (or retrieve the print capture data by case)