Description: Sensor error in coin vender change (Yen 50) Change is empty despite change is enough.
Causes: Coin jam in the change tube. Contact in the connector. Change empty sensor. Coin vender control PWB.
Remedy: Coin jam in the change tube Check visually and remedy. Contact in the connector Check the connection of the empty change sensor. Change empty sensor Replace the coin mec. Coin vender control PWB Replace the coin mec.
Code: 9140
Description: Sensor error in coin vender change (Yen 100) Change is empty despite change is enough.
Causes: Coin jam in the change tube. Contact in the connector. Change empty sensor. Coin vender control PWB.
Remedy: Coin jam in the change tube Check visually and remedy. Contact in the connector Check the connection of the empty change sensor. Change empty sensor Replace the coin mec. Coin vender control PWB Replace the coin mec.
Code: 9150
Description: Sensor error in coin vender change (Yen 500) Change is empty despite change is enough.
Causes: Change tube. Contact in the connector. Change empty sensor. Coin vender control PWB.
Remedy: Change tube Check no exchange jam is observed at the outlet and, if necessary, repair it. Contact in the connector Check the connection of the empty change sensor. Change empty sensor Replace the coin mec. Coin vender control PWB Replace the coin mec.
Code: 9160
Description: Coin vender pay-out error Coin is paid out despite the pay-out motor is determined not active.
Causes: Pay-out motor
Remedy: Replace the coin mec.
Code: 9170
Description: Coin vender pay-out sensor error Coin is paid out despite the pay-out motor is determined not active.
Remedy: Pay-out area Check no exchange jam is observed at the outlet and, if necessary, repair it. Pay-out motor Replace the coin mec. Pay-out sensor Replace the coin mec.
Code: 9500
Description: ISC PWB error A
Causes: Main PWB. ISC PWB.
Remedy: 1. Reinsert the connector if its connection is loose. Main PWB (YC25) and ISC PWB (YC4) 2. Replace the main PWB. 3. Replace the ISC PWB 4. Contact the Service Support.
Code: 9510
Description: ISC PWB error B
Causes: Main PWB. DP SHD PWB.
Remedy: 1. Reinsert the connector if its connection is loose. DP relay PWB (YC2) and DP SHD PWB (YC3) 2. Replace the main PWB. 3. Replace the DP SHD PWB. 4. Contact the Service Support.
Code: 9520
Description: ISC PWB error C
Causes: Main PWB. ISC PWB.
Remedy: 1. Reinsert the connector if its connection is loose. Main PWB (YC25) and ISC PWB (YC4) 2. Replace the main PWB. 3. Replace the ISC main PWB 4. Contact the Service Support.