Description: Developer unit type Mismatch error (Black) Improper adaptation of the main unit and developer unit is detected.
Remedy: Developer unit 1. Check if the developer unit of different models is mounted, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Developer unit - Drum/Developer relay PWB Drum/Developer relay PWB - Engine PWB(YC6) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. Drum/developer relay PWB Replace the drum/developer relay PWB Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the engine PWB.
Code: 7402
Description: Developer unit type Mismatch error (Cyan) Improper adaptation of the main unit and developer unit is detected.
Remedy: Developer unit 1. Check if the developer unit of different models is mounted, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Developer unit - Drum/Developer relay PWB Drum/Developer relay PWB - Engine PWB(YC6) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. Drum/developer relay PWB Replace the drum/developer relay PWB Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the engine PWB.
Code: 7403
Description: Developer unit type Mismatch error (Magenta) Improper adaptation of the main unit and developer unit is detected.
Remedy: Developer unit 1. Check if the developer unit of different models is mounted, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Developer unit - Drum/Developer relay PWB Drum/Developer relay PWB - Engine PWB(YC6) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. Drum/developer relay PWB Replace the drum/developer relay PWB Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the engine PWB.
Code: 7404
Description: Developer unit type mismatch error (Yellow) Improper adaptation of the main unit and developer unit is detected.
Remedy: Developer unit 1. Check if the developer unit of different models is mounted, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Developer unit - Drum/Developer relay PWB Drum/Developer relay PWB - Engine PWB(YC6) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. Drum/developer relay PWB Replace the drum/developer relay PWB Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the engine PWB.
Code: 7411
Description: Drum unit type Mismatch error (Black) Improper adaptation of the main unit and drum unit is detected.
Remedy: Drum unit 1. Check if the drum unit of different models is attached, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit - Drum/Developer relay PWB Drum/Developer relay PWB - Engine PWB(YC6) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. Drum/developer relay PWB Replace the drum/developer relay PWB Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the engine PWB.
Code: 7412
Description: Drum unit type Mismatch error (Cyan) Improper adaptation of the main unit and drum unit is detected.
Remedy: Drum unit 1. Check if the drum unit of different models is attached, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit - Drum/Developer relay PWB Drum/Developer relay PWB - Engine PWB(YC6) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. Drum/developer relay PWB Replace the drum/developer relay PWB Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the engine PWB.
Code: 7413
Description: Drum unit type Mismatch error (Magenta) Improper adaptation of the main unit and drum unit is detected.
Remedy: Drum unit 1. Check if the drum unit of different models is attached, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit - Drum/Developer relay PWB Drum/Developer relay PWB - Engine PWB(YC6) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. Drum/developer relay PWB Replace the drum/developer relay PWB Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the engine PWB.
Code: 7414
Description: Drum unit type Mismatch error (Yellow) Improper adaptation of the main unit and drum unit is detected.
Remedy: Drum unit 1. Check if the drum unit of different models is attached, and replace it to the correct one. 2. Confirm that the wiring connector is firmly connected, and if necessary, connect the connector all the way in. Drum unit - Drum/Developer relay PWB Drum/Developer relay PWB - Engine PWB(YC6) 3. If the wiring is disconnected, short-circuited or has a ground fault, replace the wire. Drum/developer relay PWB Replace the drum/developer relay PWB Engine PWB 1. Check the engine firmware and upgrade to the latest version if necessary. 2. Replace the engine PWB.